Product comparison · 2 power distribution units (pdus)

Vertiv Geist AN03E1R1-12CF18-3TL6TL6A011-D power distribution unit (PDU) 12 AC outlet(s) 0U Black vs Vertiv Geist AN03E2R0-20S203-2ST5ST5A011-D power distribution unit (PDU) 20 AC outlet(s) 0U Black

Add a product
  • 27specifications compared
  • 10differ
  • 17identical
  • 1known for one product only

Key differences

  • On/off switch
    • Geist AN03E1R1-12CF18-3TL6TL6A011-D power distribution unit (PDU) 12 AC outlet(s) 0U Black:Yes
    • Geist AN03E2R0-20S203-2ST5ST5A011-D power distribution unit (PDU) 20 AC outlet(s) 0U Black:No
  • AC outlets quantity
    • Geist AN03E1R1-12CF18-3TL6TL6A011-D power distribution unit (PDU) 12 AC outlet(s) 0U Black:12 AC outlet(s)
    • Geist AN03E2R0-20S203-2ST5ST5A011-D power distribution unit (PDU) 20 AC outlet(s) 0U Black:20 AC outlet(s)
  • Power plug
    • Geist AN03E1R1-12CF18-3TL6TL6A011-D power distribution unit (PDU) 12 AC outlet(s) 0U Black:NEMA L6-30P
    • Geist AN03E2R0-20S203-2ST5ST5A011-D power distribution unit (PDU) 20 AC outlet(s) 0U Black:NEMA 5-20P
  • AC outlet types
    • Geist AN03E1R1-12CF18-3TL6TL6A011-D power distribution unit (PDU) 12 AC outlet(s) 0U Black:C13 coupler, C19 coupler
    • Geist AN03E2R0-20S203-2ST5ST5A011-D power distribution unit (PDU) 20 AC outlet(s) 0U Black:NEMA 5-20R
  • Nominal input voltage
    • Geist AN03E1R1-12CF18-3TL6TL6A011-D power distribution unit (PDU) 12 AC outlet(s) 0U Black:200-240 V
    • Geist AN03E2R0-20S203-2ST5ST5A011-D power distribution unit (PDU) 20 AC outlet(s) 0U Black:100-120 V
  • Maximum current
    • Geist AN03E1R1-12CF18-3TL6TL6A011-D power distribution unit (PDU) 12 AC outlet(s) 0U Black:30 A
    • Geist AN03E2R0-20S203-2ST5ST5A011-D power distribution unit (PDU) 20 AC outlet(s) 0U Black:20 A
  • Output voltage
    • Geist AN03E1R1-12CF18-3TL6TL6A011-D power distribution unit (PDU) 12 AC outlet(s) 0U Black:208 V
    • Geist AN03E2R0-20S203-2ST5ST5A011-D power distribution unit (PDU) 20 AC outlet(s) 0U Black:120 V
  • Load capacity
    • Geist AN03E1R1-12CF18-3TL6TL6A011-D power distribution unit (PDU) 12 AC outlet(s) 0U Black:208 VA
    • Geist AN03E2R0-20S203-2ST5ST5A011-D power distribution unit (PDU) 20 AC outlet(s) 0U Black:120 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of AN03E1R1-12CF18-3TL6TL6A011-D, AN03E2R0-20S203-2ST5ST5A011-D
28 specifications
Design1 differ
PDU typesMonitored, SwitchedMonitored, Switched
TypeSingle-phaseSingle-phase
Rack capacity0U0U
MountingHorizontalHorizontal
Product colourBlackBlack
DisplayLEDLED
On/off switchDiffersYesNo
Ports & interfaces3 differ
AC outlets quantityDiffers12 AC outlet(s)20 AC outlet(s)
Power plugDiffersNEMA L6-30PNEMA 5-20P
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5-20R
Serial ports quantity11
Ethernet LAN (RJ-45) ports11
USB ports quantity11
Featuresidentical
LED indicatorsNoNo
Cable length3 m3 m
Management featuresidentical
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Supported network protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power4 differ
Nominal input voltageDiffers200-240 V100-120 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers30 A20 A
Output voltageDiffers208 V120 V
Load capacityDiffers208 VA120 VA
Power protection featuresKnown for oneOver currentUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)0 - 60 °C0 - 60 °C
Weight & dimensions1 differ
Width432 mm432 mm
Depth457 mm457 mm
HeightDiffers44 mm87 mm
Packaging data1 differ
Package weightDiffers10.9 kg5.44 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons