Product comparison · 2 power distribution units (pdus)

APC Easy PDU Switched 1U 16A vs APC Easy PDU Switched Zero U 32A

Add a product
  • 29specifications compared
  • 15differ
  • 14identical
  • 1known for one product only

Key differences

  • Rack capacity
    • Easy PDU Switched 1U 16A:1U
    • Easy PDU Switched Zero U 32A:0U
  • AC outlets quantity
    • Easy PDU Switched 1U 16A:8 AC outlet(s)
    • Easy PDU Switched Zero U 32A:17 AC outlet(s)
  • Power plug
    • Easy PDU Switched 1U 16A:C20 coupler
    • Easy PDU Switched Zero U 32A:IEC 60309
  • Maximum current
    • Easy PDU Switched 1U 16A:16 A
    • Easy PDU Switched Zero U 32A:32 A
  • Output voltage
    • Easy PDU Switched 1U 16A:208 V
    • Easy PDU Switched Zero U 32A:230 V
  • Load capacity
    • Easy PDU Switched 1U 16A:3680 VA
    • Easy PDU Switched Zero U 32A:7360 VA
  • Width
    • Easy PDU Switched 1U 16A:482 mm
    • Easy PDU Switched Zero U 32A:56 mm
  • Depth
    • Easy PDU Switched 1U 16A:150 mm
    • Easy PDU Switched Zero U 32A:62 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2016S, EPDU2132S
30 specifications
Design1 differ
PDU typesSwitchedSwitched
TypeSingle-phaseSingle-phase
Rack capacityDiffers1U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)17 AC outlet(s)
Power plugDiffersC20 couplerIEC 60309
AC outlet typesC13 couplerC13 coupler
Power3 differ
Nominal input voltage230 V230 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A32 A
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Output voltageDiffers208 V230 V
Load capacityDiffers3680 VA7360 VA
Number of phases11
Certificatesidentical
Compliance certificatesCE, UKCACE, UKCA
Operational conditionsidentical
Operating temperature (T-T)-5 - 50 °C-5 - 50 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Weight & dimensions4 differ
WidthDiffers482 mm56 mm
DepthDiffers150 mm62 mm
HeightDiffers44 mm1650 mm
WeightDiffers2.45 kg6.65 kg
Packaging data4 differ
Package weightDiffers3.8 kg8.15 kg
Package widthDiffers260 mm170 mm
Package depthDiffers570 mm1810 mm
Package heightDiffers680 mm1260 mm
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs8141310

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons