Product comparison · 2 power distribution units (pdus)

APC Easy PDU Switched ZeroU 16A vs APC Easy Rack PDU, Switched Metered Outlet, 0U, 3 Phase, 22kW

Add a product
  • 26specifications compared
  • 17differ
  • 9identical
  • 10known for one product only

Key differences

  • PDU types
    • Easy PDU Switched ZeroU 16A:Switched
    • Easy Rack PDU, Switched Metered Outlet, 0U, 3 Phase, 22kW:Metered, Switched
  • Type
    • Easy PDU Switched ZeroU 16A:Single-phase
    • Easy Rack PDU, Switched Metered Outlet, 0U, 3 Phase, 22kW:Three-phase
  • AC outlet types
    • Easy PDU Switched ZeroU 16A:C13 coupler
    • Easy Rack PDU, Switched Metered Outlet, 0U, 3 Phase, 22kW:C13 coupler, C19 coupler
  • Nominal input voltage
    • Easy PDU Switched ZeroU 16A:230 V
    • Easy Rack PDU, Switched Metered Outlet, 0U, 3 Phase, 22kW:400 V
  • Maximum current
    • Easy PDU Switched ZeroU 16A:16 A
    • Easy Rack PDU, Switched Metered Outlet, 0U, 3 Phase, 22kW:32 A
  • Output voltage
    • Easy PDU Switched ZeroU 16A:230 V
    • Easy Rack PDU, Switched Metered Outlet, 0U, 3 Phase, 22kW:200-240 V
  • Load capacity
    • Easy PDU Switched ZeroU 16A:3680 VA
    • Easy Rack PDU, Switched Metered Outlet, 0U, 3 Phase, 22kW:22000 VA
  • Operating temperature (T-T)
    • Easy PDU Switched ZeroU 16A:-5 - 50 °C
    • Easy Rack PDU, Switched Metered Outlet, 0U, 3 Phase, 22kW:-5 - 45 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2116S, EPDU2232SMBO
36 specifications
Design2 differ
PDU typesDiffersSwitchedMetered, Switched
TypeDiffersSingle-phaseThree-phase
Rack capacity0U0U
MountingVerticalVertical
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces1 differ
AC outlets quantity24 AC outlet(s)24 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Power4 differ
Nominal input voltageDiffers230 V400 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A32 A
Output voltageDiffers230 V200-240 V
Load capacityDiffers3680 VA22000 VA
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Number of phasesKnown for one1Unknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 50 °C-5 - 45 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitudeDiffers0 - 3000 m0 - 15000 m
Weight & dimensions4 differ
WidthDiffers56 mm55 mm
DepthDiffers62 mm56 mm
HeightDiffers1650 mm1800 mm
WeightDiffers6.1 kg8.68 kg
Packaging data4 differ
Package weightDiffers7.6 kg9.85 kg
Package widthDiffers170 mm195 mm
Package depthDiffers1810 mm130 mm
Package heightDiffers1260 mm2030 mm
Certificatesidentical
Compliance certificatesKnown for oneCE, UKCAUnknown — not stated by the source
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one1088Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons