Product comparison · 2 power distribution units (pdus)

Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309 vs Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309

Add a product
  • 20specifications compared
  • 4differ
  • 16identical
  • 1known for one product only

Key differences

The Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309 has 820 mm more height than the Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309 (1736.5 mm vs 916.5 mm). PDU types: Metered on the Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309, Metered, Switched on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309. AC outlets quantity: 19 AC outlet(s) on the Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309, 24 AC outlet(s) on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309. AC outlet types: C13 coupler, C19 coupler on the Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309, C13 coupler on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309.

  • PDU types
    • MPH2 Rack PDU, branch metered, 0U, input IEC 60309:Metered
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:Metered, Switched
  • AC outlets quantity
    • MPH2 Rack PDU, branch metered, 0U, input IEC 60309:19 AC outlet(s)
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:24 AC outlet(s)
  • AC outlet types
    • MPH2 Rack PDU, branch metered, 0U, input IEC 60309:C13 coupler, C19 coupler
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:C13 coupler
  • Height
    • MPH2 Rack PDU, branch metered, 0U, input IEC 60309:916.5 mm
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:1736.5 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of MPHB3242, MPHR1242
21 specifications
Design1 differ
PDU typesDiffersMeteredMetered, Switched
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers19 AC outlet(s)24 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler
Output connectionsKnown for one17 x C13 & 2 x C19Unknown — not stated by the source
Featuresidentical
LED indicatorsYesYes
Management featuresidentical
Management platformWeb, CLI, SNMP, SSH, TelnetWeb, CLI, SNMP, SSH, Telnet
Poweridentical
Nominal input voltage230 V230 V
Maximum current16 A16 A
Power protection featuresOver currentOver current
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationUL, CSA, CE, REACH, FCC Class A, CB, WEEE, ISTAUL, CSA, CE, REACH, FCC Class A, CB, WEEE, ISTA
Operational conditionsidentical
Operating temperature (T-T)0 - 60 °C0 - 60 °C
Storage temperature (T-T)-25 - 85 °C-25 - 85 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Weight & dimensions1 differ
Width56 mm56 mm
Depth50 mm50 mm
HeightDiffers916.5 mm1736.5 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.