Product comparison · 2 power distribution units (pdus)

Vertiv Geist MG03E4B0-26PJ63-2PS6B2A10-S-RC power distribution unit (PDU) 26 AC outlet(s) Black vs Vertiv Geist MG03E4W1-30PN63-3PS56B2A10-S-A-RC power distribution unit (PDU) 30 AC outlet(s) Black

Add a product
  • 33specifications compared
  • 9differ
  • 24identical
  • 0known for one product only

Key differences

  • Type
    • Geist MG03E4B0-26PJ63-2PS6B2A10-S-RC power distribution unit (PDU) 26 AC outlet(s) Black:Single-phase
    • Geist MG03E4W1-30PN63-3PS56B2A10-S-A-RC power distribution unit (PDU) 30 AC outlet(s) Black:Three-phase
  • On/off switch
    • Geist MG03E4B0-26PJ63-2PS6B2A10-S-RC power distribution unit (PDU) 26 AC outlet(s) Black:No
    • Geist MG03E4W1-30PN63-3PS56B2A10-S-A-RC power distribution unit (PDU) 30 AC outlet(s) Black:Yes
  • AC outlets quantity
    • Geist MG03E4B0-26PJ63-2PS6B2A10-S-RC power distribution unit (PDU) 26 AC outlet(s) Black:26 AC outlet(s)
    • Geist MG03E4W1-30PN63-3PS56B2A10-S-A-RC power distribution unit (PDU) 30 AC outlet(s) Black:30 AC outlet(s)
  • Nominal input voltage
    • Geist MG03E4B0-26PJ63-2PS6B2A10-S-RC power distribution unit (PDU) 26 AC outlet(s) Black:200 - 240 V
    • Geist MG03E4W1-30PN63-3PS56B2A10-S-A-RC power distribution unit (PDU) 30 AC outlet(s) Black:200-240/346-415V WYE
  • Maximum current
    • Geist MG03E4B0-26PJ63-2PS6B2A10-S-RC power distribution unit (PDU) 26 AC outlet(s) Black:16 A
    • Geist MG03E4W1-30PN63-3PS56B2A10-S-A-RC power distribution unit (PDU) 30 AC outlet(s) Black:32 A
  • Maximum power
    • Geist MG03E4B0-26PJ63-2PS6B2A10-S-RC power distribution unit (PDU) 26 AC outlet(s) Black:3600 W
    • Geist MG03E4W1-30PN63-3PS56B2A10-S-A-RC power distribution unit (PDU) 30 AC outlet(s) Black:22000 W
  • Depth
    • Geist MG03E4B0-26PJ63-2PS6B2A10-S-RC power distribution unit (PDU) 26 AC outlet(s) Black:51 mm
    • Geist MG03E4W1-30PN63-3PS56B2A10-S-A-RC power distribution unit (PDU) 30 AC outlet(s) Black:58 mm
  • Height
    • Geist MG03E4B0-26PJ63-2PS6B2A10-S-RC power distribution unit (PDU) 26 AC outlet(s) Black:1683 mm
    • Geist MG03E4W1-30PN63-3PS56B2A10-S-A-RC power distribution unit (PDU) 30 AC outlet(s) Black:1829 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of MG03E4B0-26PJ63-2PS6B2A10-S-RC, MG03E4W1-30PN63-3PS56B2A10-S-A-RC
33 specifications
Design2 differ
PDU typesMonitoredMonitored
TypeDiffersSingle-phaseThree-phase
MountingVerticalVertical
Product colourBlackBlack
DisplayLEDLED
On/off switchDiffersNoYes
Ports & interfaces1 differ
AC outlets quantityDiffers26 AC outlet(s)30 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesC13 coupler, C19 coupler, IEC 60309C13 coupler, C19 coupler, IEC 60309
Serial ports quantity11
Ethernet LAN (RJ-45) ports11
USB ports quantity11
Featuresidentical
Daisy chainYesYes
Reset buttonYesYes
LED indicatorsYesYes
Cable length3 m3 m
Management featuresidentical
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Supported network protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers200 - 240 V200-240/346-415V WYE
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A32 A
Output voltage230 V230 V
Maximum powerDiffers3600 W22000 W
Circuit breakerYesYes
Certificatesidentical
Compliance certificatesCE, RoHS, UKCACE, RoHS, UKCA
CertificationANSI C12.1, IEC 62053-21, IEC 62368-1, EN 55032, EN 55035ANSI C12.1, IEC 62053-21, IEC 62368-1, EN 55032, EN 55035
Sustainabilityidentical
Sustainability complianceYesYes
Operational conditionsidentical
Operating temperature (T-T)0 - 60 °C0 - 60 °C
Weight & dimensions2 differ
Width51 mm51 mm
DepthDiffers51 mm58 mm
HeightDiffers1683 mm1829 mm
Packaging data1 differ
Package weightDiffers6.8 kg7.71 kg
Logistics dataidentical
Warranty period5 year(s)5 year(s)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.