Product comparison · 2 power distribution units (pdus)

ATEN 1U 10A 12Port Basic PDU vs Vertiv Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U

Add a product
  • 12specifications compared
  • 11differ
  • 1identical
  • 27known for one product only

Key differences

The ATEN 1U 10A 12Port Basic PDU has 1 U more rack capacity than the Vertiv Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U (1U vs 0U). The Vertiv Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U has 100 -240 V more nominal input voltage than the ATEN 1U 10A 12Port Basic PDU (200-240 V vs 100 -240 V). The Vertiv Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U has 50 A more maximum current than the ATEN 1U 10A 12Port Basic PDU (60 A vs 10 A). PDU types: Basic on the ATEN 1U 10A 12Port Basic PDU, Monitored on the Vertiv Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U. AC outlets quantity: 12 AC outlet(s) on the ATEN 1U 10A 12Port Basic PDU, 24 AC outlet(s) on the Vertiv Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U.

  • PDU types
    • 1U 10A 12Port Basic PDU:Basic
    • Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U:Monitored
  • Rack capacity
    • 1U 10A 12Port Basic PDU:1U
    • Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U:0U
  • AC outlets quantity
    • 1U 10A 12Port Basic PDU:12 AC outlet(s)
    • Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U:24 AC outlet(s)
  • AC outlet types
    • 1U 10A 12Port Basic PDU:C13 coupler
    • Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U:C13 coupler, C19 coupler
  • Nominal input voltage
    • 1U 10A 12Port Basic PDU:100 -240 V
    • Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U:200-240 V
  • AC input frequency
    • 1U 10A 12Port Basic PDU:50 - 60 Hz
    • Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U:50/60 Hz
  • Maximum current
    • 1U 10A 12Port Basic PDU:10 A
    • Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U:60 A
  • Width
    • 1U 10A 12Port Basic PDU:480 mm
    • Geist NR30049L power distribution unit (PDU) 24 AC outlet(s) 0U:58 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PE0112G, NR30049L
39 specifications
Design2 differ
PDU typesDiffersBasicMonitored
Rack capacityDiffers1U0U
Housing materialKnown for oneAluminiumUnknown — not stated by the source
Product colourKnown for oneBlackUnknown — not stated by the source
MountingKnown for oneUnknown — not stated by the sourceVertical
Ports & interfaces2 differ
AC outlets quantityDiffers12 AC outlet(s)24 AC outlet(s)
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Featuresidentical
Cable length3 m3 m
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Power3 differ
Nominal input voltageDiffers100 -240 V200-240 V
AC input frequencyDiffers50 - 60 Hz50/60 Hz
Maximum currentDiffers10 A60 A
Nominal output voltageKnown for one240 VUnknown — not stated by the source
Load capacityKnown for one2400 VAUnknown — not stated by the source
Power protection featuresKnown for oneOver currentUnknown — not stated by the source
Output voltageKnown for oneUnknown — not stated by the source208 V
Certificates1 differ
CertificationDiffersCE Class A CE,LVDRoHS FCC Part 15 Class A UL & c-UL Listed 62368-1
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers480 mm58 mm
DepthDiffers450 mm66 mm
HeightDiffers44 mm1778 mm
WeightKnown for one920 gUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneACUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one1.18 kgUnknown — not stated by the source
Package widthKnown for one112 mmUnknown — not stated by the source
Package depthKnown for one697 mmUnknown — not stated by the source
Package heightKnown for one82 mmUnknown — not stated by the source
Logistics dataidentical
Master (outer) case net weightKnown for one9.2 kgUnknown — not stated by the source
Master (outer) case widthKnown for one595 mmUnknown — not stated by the source
Master (outer) case lengthKnown for one710 mmUnknown — not stated by the source
Master (outer) case heightKnown for one188 mmUnknown — not stated by the source
Master (outer) case gross weightKnown for one13 kgUnknown — not stated by the source
Products per master (outer) caseKnown for one10 pc(s)Unknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons