Product comparison · 2 power distribution units (pdus)

APC Rack ATS, 230V, 32A, IEC309 in, (16)C13 (2)C19 out vs Vertiv PM 1000 Vertical Model

Add a product
  • 13specifications compared
  • 12differ
  • 1identical
  • 13known for one product only

Key differences

  • Mounting
    • Rack ATS, 230V, 32A, IEC309 in, (16)C13 (2)C19 out:Horizontal
    • PM 1000 Vertical Model:Vertical
  • Input connection type
    • Rack ATS, 230V, 32A, IEC309 in, (16)C13 (2)C19 out:IEC 309 32A 2P+E
    • PM 1000 Vertical Model:IEC309
  • Cable length
    • Rack ATS, 230V, 32A, IEC309 in, (16)C13 (2)C19 out:2.44 m
    • PM 1000 Vertical Model:3 m
  • Maximum current
    • Rack ATS, 230V, 32A, IEC309 in, (16)C13 (2)C19 out:32 A
    • PM 1000 Vertical Model:16 A
  • Maximum input current per phase
    • Rack ATS, 230V, 32A, IEC309 in, (16)C13 (2)C19 out:32 A
    • PM 1000 Vertical Model:16 A
  • Operating temperature (T-T)
    • Rack ATS, 230V, 32A, IEC309 in, (16)C13 (2)C19 out:-5 - 45 °C
    • PM 1000 Vertical Model:10 - 45 °C
  • Storage temperature (T-T)
    • Rack ATS, 230V, 32A, IEC309 in, (16)C13 (2)C19 out:-25 - 65 °C
    • PM 1000 Vertical Model:-40 - 65 °C
  • Width
    • Rack ATS, 230V, 32A, IEC309 in, (16)C13 (2)C19 out:432 mm
    • PM 1000 Vertical Model:5.6 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of Rack ATS, 230V, 32A, IEC309 in, (16)C13 (2)C19 out, PM 1000 Vertical Model
26 specifications
Design1 differ
MountingDiffersHorizontalVertical
Ports & interfaces2 differ
Input connection typeDiffersIEC 309 32A 2P+EIEC309
Output connectionsDiffers16 x IEC 320 C13 2 x IEC 320 C19(21) C13 (3) C19
I/O portsKnown for oneUnknown — not stated by the source1 x 10/100/1000 Ethernet 2 x RJ-45
Features1 differ
Cable lengthDiffers2.44 m3 m
Power2 differ
Nominal input voltageKnown for one230 VUnknown — not stated by the source
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers32 A16 A
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Maximum input current per phaseDiffers32 A16 A
Maximum total current draw per phaseKnown for one32 AUnknown — not stated by the source
Certificates1 differ
CertificationDiffersEN 55022 Class A, FCC Part 15 Class A RoHS 7bUL, FCC, cUL, CE, VCCI, C-Tick, CB
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 45 °C10 - 45 °C
Storage temperature (T-T)Differs-25 - 65 °C-40 - 65 °C
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers432 mm5.6 mm
DepthDiffers236 mm8 mm
HeightDiffers88 mm167.6 mm
WeightKnown for one6.86 kgUnknown — not stated by the source
Weight (imperial)Known for oneUnknown — not stated by the source6.71 kg (14.8 lbs)
Packaging dataidentical
Package weightKnown for one9.36 kgUnknown — not stated by the source
Package widthKnown for one613 mmUnknown — not stated by the source
Package depthKnown for one356 mmUnknown — not stated by the source
Package heightKnown for one184 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.