Product comparison · 2 power distribution units (pdus)

APC RACK ATS, 200-208V vs Vertiv Cyclades PM20i-20A IPDU - 20 Port Vertical

Add a product
  • 10specifications compared
  • 9differ
  • 1identical
  • 10known for one product only

Key differences

  • Input connection type
    • RACK ATS, 200-208V:NEMA L6-20P
    • Cyclades PM20i-20A IPDU - 20 Port Vertical:IEC320-C20
  • Operating temperature (T-T)
    • RACK ATS, 200-208V:-5 - 45 °C
    • Cyclades PM20i-20A IPDU - 20 Port Vertical:10 - 50 °C
  • Storage temperature (T-T)
    • RACK ATS, 200-208V:-25 - 65 °C
    • Cyclades PM20i-20A IPDU - 20 Port Vertical:-40 - 85 °C
  • Width
    • RACK ATS, 200-208V:432 mm
    • Cyclades PM20i-20A IPDU - 20 Port Vertical:50.8 mm
  • Depth
    • RACK ATS, 200-208V:229 mm
    • Cyclades PM20i-20A IPDU - 20 Port Vertical:71.1 mm
  • Height
    • RACK ATS, 200-208V:44 mm
    • Cyclades PM20i-20A IPDU - 20 Port Vertical:1676.4 mm
  • Weight
    • RACK ATS, 200-208V:5.02 kg
    • Cyclades PM20i-20A IPDU - 20 Port Vertical:7.73 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of RACK ATS, 200-208V, Cyclades PM20i-20A IPDU - 20 Port Vertical
20 specifications
Designidentical
Product colourBlackBlack
MountingKnown for oneUnknown — not stated by the sourceVertical
Ports & interfaces2 differ
Input connection typeDiffersNEMA L6-20PIEC320-C20
Output connectionsDiffers8x IEC 320 C13 1x IEC 320 C1920x IEC320-C13
I/O portsKnown for oneUnknown — not stated by the source2x RS-232 (RJ45, 9600 bps)
Featuresidentical
Cable lengthKnown for one2.44 mUnknown — not stated by the source
Poweridentical
AC input frequencyKnown for one47/63 HzUnknown — not stated by the source
Maximum input current per phaseKnown for one20 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one20 AUnknown — not stated by the source
Nominal input voltageKnown for oneUnknown — not stated by the source208 V
Maximum currentKnown for oneUnknown — not stated by the source20 A
Certificates1 differ
CertificationDiffersEN 55022 Class A,FCC Part 15 Class A RoHS 7b ExemptionFCC Class A CSA (UL)
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 45 °C10 - 50 °C
Storage temperature (T-T)Differs-25 - 65 °C-40 - 85 °C
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers432 mm50.8 mm
DepthDiffers229 mm71.1 mm
HeightDiffers44 mm1676.4 mm
WeightDiffers5.02 kg7.73 kg