Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets vs APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets

Add a product
  • 28specifications compared
  • 18differ
  • 10identical
  • 12known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (2U vs 0U). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 40 A more maximum current than the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets (100 A vs 60 A). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 12,600 VA more load capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (41400 VA vs 28800 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Metered-by-outlet on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets. Mounting: Vertical on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Horizontal on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Metered-by-outlet
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:0U
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:2U
  • Mounting
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Vertical
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Horizontal
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:18 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IEC309
  • International Protection (IP) code
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IP67
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IP44
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 3 phases
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:60 A

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets
40 specifications
Design3 differ
PDU typesDiffersMeteredMetered-by-outlet
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers30 AC outlet(s)18 AC outlet(s)
Power plugDiffersIEC 60309IEC309
AC outlet typesDiffersC15 coupler, C13 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 60 A
Features1 differ
International Protection (IP) codeDiffersIP67IP44
Power4 differ
Nominal input voltageDiffers208 V415 3 phases
Maximum currentDiffers100 A60 A
Output voltageDiffers208 V415 V AC 3 phases
Load capacityDiffers28800 VA41400 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Weight & dimensions4 differ
WidthDiffers56 mm443 mm
DepthDiffers75 mm750 mm
HeightDiffers1900 mm85 mm
WeightDiffers14 kg16.3 kg
Packaging data3 differ
Package weightDiffers19.8 kg22.8 kg
Package widthDiffers350 mm600 mm
Package heightDiffers2110 mm940 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceYes
SCIP numberKnown for oneUnknown — not stated by the source7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo