Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet vs APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet

Add a product
  • 38specifications compared
  • 14differ
  • 24identical
  • 6known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 28 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (60 A vs 32 A). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 170 V more nominal output voltage than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (400 V vs 230 V). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 10 V more output voltage than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (240 V vs 230 V). AC outlets quantity: 42 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet. Input connection type: IEC 60309 30 A 3P + N + PE on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, IEC 60309 32 A 2P + PE on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet.

  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:42 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:40 AC outlet(s)
  • Input connection type
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:IEC 60309 30 A 3P + N + PE
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:IEC 60309 32 A 2P + PE
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:415 3 phases; 400 3 phases
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 1 phase
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:60 A
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:32 A
  • Nominal output voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:400 V
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:240 V
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:34600 VA
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:7400 VA
  • Number of phases
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:3
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:1

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet
44 specifications
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)40 AC outlet(s)
Input connection typeDiffersIEC 60309 30 A 3P + N + PEIEC 60309 32 A 2P + PE
Power6 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases230 1 phase
Maximum currentDiffers60 A32 A
Nominal output voltageDiffers400 V230 V
Output voltageDiffers240 V230 V
Load capacityDiffers34600 VA7400 VA
Number of phasesDiffers31
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source23 - 140 °F
Storage temperature (T-T)Known for oneUnknown — not stated by the source-25 - 65 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3048 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Weight & dimensions2 differ
HeightDiffers1780 mm1490 mm
WeightDiffers9.6 kg7.5 kg
Packaging data4 differ
Package weightDiffers17 kg8.2 kg
Package widthDiffers132 mm116 mm
Package depthDiffers262 mm208 mm
Package heightDiffers2110 mm1720 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.