Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet vs APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet

Add a product
  • 38specifications compared
  • 14differ
  • 24identical
  • 6known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 28 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (60 A vs 32 A). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 170 V more nominal output voltage than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (400 V vs 230 V). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 10 V more output voltage than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (240 V vs 230 V). AC outlets quantity: 42 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet. Input connection type: IEC 60309 30 A 3P + N + PE on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, IEC 60309 32 A 2P + PE on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet.

  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:42 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:40 AC outlet(s)
  • Input connection type
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:IEC 60309 30 A 3P + N + PE
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:IEC 60309 32 A 2P + PE
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:415 3 phases; 400 3 phases
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 1 phase
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:60 A
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:32 A
  • Nominal output voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:400 V
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:240 V
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:34600 VA
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:7400 VA
  • Number of phases
    • NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:3
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:1

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet
44 specifications
Designidentical
PDU typesMeteredMetered
TypeThree-phaseThree-phase
Rack capacity0U0U
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)40 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports55
USB ports quantity11
Input connection typeDiffersIEC 60309 30 A 3P + N + PEIEC 60309 32 A 2P + PE
Featuresidentical
Cable length3 m3 m
Management featuresidentical
Management platformNMC3NMC3
Power6 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases230 1 phase
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers60 A32 A
Nominal output voltageDiffers400 V230 V
Output voltageDiffers240 V230 V
Load capacityDiffers34600 VA7400 VA
Number of phasesDiffers31
Battery replacement accessibilityNon-removableNon-removable
Certificatesidentical
Compliance certificatesRoHS, REACH, WEEERoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceYesYes
CertificationUKCAUKCA
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source23 - 140 °F
Storage temperature (T-T)Known for oneUnknown — not stated by the source-25 - 65 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3048 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Weight & dimensions2 differ
Width56 mm56 mm
Depth75 mm75 mm
HeightDiffers1780 mm1490 mm
WeightDiffers9.6 kg7.5 kg
Packaging data4 differ
Package weightDiffers17 kg8.2 kg
Package widthDiffers132 mm116 mm
Package depthDiffers262 mm208 mm
Package heightDiffers2110 mm1720 mm
Technical detailsidentical
Preferred mounting positionno preferenceno preference
Removable batteryNoNo
Packaging without single use plasticNoNo
SCIP number31346aed-552c-4a16-81d9-e683a383b6da31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingNoNo
Take-back systemNoNo
Logistics dataidentical
Country of originUnited StatesUnited States
Customs product code (TARIC)85371098998537109899