Product comparison · 2 power distribution units (pdus)

APC APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black vs APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet

Add a product
  • 22specifications compared
  • 14differ
  • 8identical
  • 25known for one product only

Key differences

  • AC outlets quantity
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:40 AC outlet(s)
  • Nominal input voltage
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:200 - 240 V
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 1 phase
  • Maximum current
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:60 A
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:32 A
  • Nominal output voltage
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:208 V
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
  • Output voltage
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:208 V
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
  • Load capacity
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:17300 VA
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:7400 VA
  • Operating temperature (T-T)
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:-5 - 60 °F
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:23 - 140 °F
  • Height
    • APDU11452ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:1780 mm
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:1490 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of APDU11452ME, NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet
47 specifications
Designidentical
PDU typesMeteredMetered
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacity0U0U
Product colourBlackBlack
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)40 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
USB ports quantityKnown for oneUnknown — not stated by the source1
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 60309 32 A 2P + PE
Featuresidentical
Cable length3 m3 m
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power5 differ
Nominal input voltageDiffers200 - 240 V230 1 phase
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers60 A32 A
Nominal output voltageDiffers208 V230 V
Output voltageDiffers208 V230 V
Load capacityDiffers17300 VA7400 VA
Number of phasesKnown for oneUnknown — not stated by the source1
Battery replacement accessibilityKnown for oneUnknown — not stated by the sourceNon-removable
Maximum powerKnown for one17300 WUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
CertificationKnown for oneUnknown — not stated by the sourceUKCA
Operational conditions1 differ
Operating temperature (T-T)Differs-5 - 60 °F23 - 140 °F
Storage temperature (T-T)Known for oneUnknown — not stated by the source-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3048 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Weight & dimensions2 differ
Width56 mm56 mm
Depth75 mm75 mm
HeightDiffers1780 mm1490 mm
WeightDiffers10.7 kg7.5 kg
Packaging data4 differ
Package weightDiffers13.7 kg8.2 kg
Package widthDiffers132 mm116 mm
Package depthDiffers262 mm208 mm
Package heightDiffers1980 mm1720 mm
Technical detailsidentical
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Removable batteryKnown for oneUnknown — not stated by the sourceNo
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceNo
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons