Product comparison · 2 power distribution units (pdus)

APC AP8661 power distribution unit (PDU) 24 AC outlet(s) 0U Black vs APC Switched Rack PDU

Add a product
  • 27specifications compared
  • 9differ
  • 18identical
  • 10known for one product only

Key differences

  • Power plug
    • AP8661 power distribution unit (PDU) 24 AC outlet(s) 0U Black:NEMA L21-20P
    • Switched Rack PDU:IEC309
  • Nominal input voltage
    • AP8661 power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 V
    • Switched Rack PDU:230 V
  • Maximum current
    • AP8661 power distribution unit (PDU) 24 AC outlet(s) 0U Black:20 A
    • Switched Rack PDU:32 A
  • Nominal output voltage
    • AP8661 power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 V
    • Switched Rack PDU:230 V
  • Weight
    • AP8661 power distribution unit (PDU) 24 AC outlet(s) 0U Black:7.14 kg
    • Switched Rack PDU:8.23 kg
  • Package weight
    • AP8661 power distribution unit (PDU) 24 AC outlet(s) 0U Black:9.41 kg
    • Switched Rack PDU:10.5 kg
  • Total carbon footprint (kg of CO2e)
    • AP8661 power distribution unit (PDU) 24 AC outlet(s) 0U Black:8613.71
    • Switched Rack PDU:8595.81

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8661, Switched Rack PDU
37 specifications
Design1 differ
PDU typesDiffersSwitchedMetered, Metered-by-outlet, Switched
TypeKnown for oneUnknown — not stated by the sourceSingle-phase
Rack capacity0U0U
MountingKnown for oneUnknown — not stated by the sourceVertical
Product colourBlackBlack
Ports & interfaces1 differ
AC outlets quantity24 AC outlet(s)24 AC outlet(s)
Power plugDiffersNEMA L21-20PIEC309
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler, C19 coupler
Featuresidentical
Cable length3 m3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Outlet controlKnown for oneUnknown — not stated by the sourceLock-out, Recycle, Turn off, Turn on
Power3 differ
Nominal input voltageDiffers208 V230 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers20 A32 A
Nominal output voltageDiffers208 V230 V
Load capacityKnown for oneUnknown — not stated by the source7680 VA
Maximum input current per phaseKnown for oneUnknown — not stated by the source32 A
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source32 A
Maximum powerKnown for oneUnknown — not stated by the source7680 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDifferscUL,FCC Part 15 A,ICES-003,UL,VCCI AEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE
Operational conditionsidentical
Operating temperature (T-T)-5 - 45 °C-5 - 45 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Weight & dimensions1 differ
Width56 mm56 mm
Depth51 mm51 mm
Height1829 mm1829 mm
WeightDiffers7.14 kg8.23 kg
Packaging data1 differ
Package weightDiffers9.41 kg10.5 kg
Package width162 mm162 mm
Package depth118 mm118 mm
Package height2038 mm2038 mm
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs8613.718595.81

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons