The APC 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW has 115 A more maximum input current per phase than the APC Rack PDU, Metered, Zero U, 16.2KW, 208V (175 A vs 60 A). The APC 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW has 130 A more maximum total current draw per phase than the APC Rack PDU, Metered, Zero U, 16.2KW, 208V (175 A vs 45 A). The APC 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW has 503 mm more width than the APC Rack PDU, Metered, Zero U, 16.2KW, 208V (559 mm vs 56 mm). Output connections: 1 x Hard Wire 3-wire (3PH) on the APC 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW, 3x IEC 320 C13 12x IEC 320 C19 on the APC Rack PDU, Metered, Zero U, 16.2KW, 208V. Operating temperature (T-T): 0 - 40 °C on the APC 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW, -5 - 60 °C on the APC Rack PDU, Metered, Zero U, 16.2KW, 208V.

  • Maximum input current per phase
    • 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW:175 A
    • Rack PDU, Metered, Zero U, 16.2KW, 208V:60 A
  • Maximum total current draw per phase
    • 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW:175 A
    • Rack PDU, Metered, Zero U, 16.2KW, 208V:45 A
  • Operating temperature (T-T)
    • 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW:0 - 40 °C
    • Rack PDU, Metered, Zero U, 16.2KW, 208V:-5 - 60 °C
  • Storage temperature (T-T)
    • 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW:-15 - 40 °C
    • Rack PDU, Metered, Zero U, 16.2KW, 208V:-25 - 65 °C
  • Width
    • 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW:559 mm
    • Rack PDU, Metered, Zero U, 16.2KW, 208V:56 mm
  • Depth
    • 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW:546 mm
    • Rack PDU, Metered, Zero U, 16.2KW, 208V:73 mm
  • Height
    • 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW:432 mm
    • Rack PDU, Metered, Zero U, 16.2KW, 208V:1778 mm
  • Weight
    • 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW:2.82 kg
    • Rack PDU, Metered, Zero U, 16.2KW, 208V:9.3 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of 3-Pole Circuit Breaker, 175A, T3 Type for Symmetra PX250/500kW, Rack PDU, Metered, Zero U, 16.2KW, 208V
21 specifications
Ports & interfaces1 differ
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 60A 3P+PE
Output connectionsDiffers1 x Hard Wire 3-wire (3PH)3x IEC 320 C13 12x IEC 320 C19
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source0.91 m
Power2 differ
Nominal input voltageKnown for oneUnknown — not stated by the source208 V
AC input frequencyKnown for oneUnknown — not stated by the source50 - 60 Hz
Nominal output voltageKnown for oneUnknown — not stated by the source208 V
Load capacityKnown for oneUnknown — not stated by the source16200 VA
Maximum input current per phaseDiffers175 A60 A
Maximum total current draw per phaseDiffers175 A45 A
Certificates1 differ
CertificationDiffersCE, UL Listed RoHScUL Listed,CSA C22.2 No. 60950-1-03,FCC Part 15 Class A,ICES-003,Industry Canada,UL 60950-1,UL Listed,VCCI Class A, RoHS 7b
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C-5 - 60 °C
Storage temperature (T-T)Differs-15 - 40 °C-25 - 65 °C
Weight & dimensions4 differ
WidthDiffers559 mm56 mm
DepthDiffers546 mm73 mm
HeightDiffers432 mm1778 mm
WeightDiffers2.82 kg9.3 kg
Weight (imperial)Known for one2.77 kg (6.1 lbs)Unknown — not stated by the source
Packaging dataidentical
Package weightKnown for one3.7 kgUnknown — not stated by the source
Package widthKnown for one559 mmUnknown — not stated by the source
Package depthKnown for one546 mmUnknown — not stated by the source
Package heightKnown for one432 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.