Product comparison · 2 uninterruptible power supplies (upss)

ATEN OL1000LV uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA vs ATEN OL3000LV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA

Add a product
  • 40specifications compared
  • 11differ
  • 29identical
  • 0known for one product only

Key differences

  • Output power capacity
    • OL1000LV uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:1 kVA
    • OL3000LV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
  • Output power
    • OL1000LV uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:1000 W
    • OL3000LV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2880 W
  • Maximum current
    • OL1000LV uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:9.3 A
    • OL3000LV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:26.4 A
  • Output power factor
    • OL1000LV uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:1
    • OL3000LV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:0.96
  • AC outlet types
    • OL1000LV uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:NEMA 5-15R
    • OL3000LV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:NEMA L5-20R, NEMA L5-30R
  • AC outlets quantity
    • OL1000LV uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:8 AC outlet(s)
    • OL3000LV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:9 AC outlet(s)
  • Number of batteries supported
    • OL1000LV uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:2
    • OL3000LV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:6
  • Typical backup time at full load
    • OL1000LV uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:2.95 min
    • OL3000LV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2.96 min

Side by side

Differences highlightedShow differences only (on)
Comparison of OL1000LV, OL3000LV
40 specifications
Features4 differ
Output power capacityDiffers1 kVA3 kVA
Output powerDiffers1000 W2880 W
Maximum currentDiffers9.3 A26.4 A
Output power factorDiffers10.96
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5-15RNEMA L5-20R, NEMA L5-30R
AC outlets quantityDiffers8 AC outlet(s)9 AC outlet(s)
Battery2 differ
Number of batteries supportedDiffers26
Typical backup time at full loadDiffers2.95 min2.96 min
Weight & dimensions3 differ
WidthDiffers438 mm630 mm
DepthDiffers410 mm438 mm
WeightDiffers12.9 kg29.5 kg