Product comparison · 2 uninterruptible power supplies (upss)

APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA vs APC BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA

Add a product
  • 57specifications compared
  • 15differ
  • 42identical
  • 5known for one product only

Key differences

The APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA has 0.45 kVA more output power capacity than the APC BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA (1.4 kVA vs 0.95 kVA). The APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA has 220 W more output power than the APC BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA (700 W vs 480 W). The APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA has 2 A more maximum current than the APC BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA (6 A vs 4 A). Audible alarm modes: Overload alarm on the APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA, Low battery alarm, Overload alarm on the APC BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA. LED indicators: Battery replacement on the APC BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA, Yes on the APC BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA.

  • Output power capacity
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:1.4 kVA
    • BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA:0.95 kVA
  • Output power
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:700 W
    • BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA:480 W
  • Maximum current
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:6 A
    • BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA:4 A
  • Efficiency
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:97.4%
    • BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA:97.1%
  • Number of output IEC jumpers
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:2
    • BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA:1
  • Battery capacity
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:165 VAh
    • BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA:76 VAh
  • Number of batteries supported
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:2
    • BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA:1
  • Typical backup time at full load
    • BX1400U-MS uninterruptible power supply (UPS) Line-Interactive 1.4 kVA:2.4 min
    • BX950U-MS uninterruptible power supply (UPS) Line-Interactive 0.95 kVA:1.3 min

Side by side

Differences highlightedShow differences only (off)
Comparison of BX1400U-MS, BX950U-MS
62 specifications
Features5 differ
UPS topologyLine-InteractiveLine-Interactive
Output power capacityDiffers1.4 kVA0.95 kVA
Output powerDiffers700 W480 W
WaveformSineSine
Input operation voltage (min)150 V150 V
Input operation voltage (max)280 V280 V
Input frequency50/60 Hz50/60 Hz
Output frequency regulationKnown for one50/60 HzUnknown — not stated by the source
Automatic Voltage Regulation (AVR)YesYes
Maximum currentDiffers6 A4 A
Surge energy rating273 J273 J
Hold time (max)10 ms10 ms
Hold time (min)8 ms8 ms
EfficiencyDiffers97.4%97.1%
Input power factorKnown for one0.5Unknown — not stated by the source
Noise level45 dB45 dB
Surge protectionYesYes
Surge protection featuresFax, ModemFax, Modem
Audible alarm(s)YesYes
Audible alarm modesDiffersOverload alarmLow battery alarm, Overload alarm
Auto-restartKnown for oneYesUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesC13 couplerC13 coupler
Power plugC14 couplerC14 coupler
AC outlets quantity6 AC outlet(s)6 AC outlet(s)
Number of output IEC jumpersDiffers21
USB portYesYes
Battery4 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacityDiffers165 VAh76 VAh
Battery voltage12 V12 V
Number of batteries supportedDiffers21
Typical backup time at full loadDiffers2.4 min1.3 min
Typical backup time at half loadDiffers11.2 min7.5 min
Battery life (max)5 year(s)5 year(s)
Battery recharge time8 h8 h
Automatic battery testYesYes
Design1 differ
Form factorTowerTower
Product colourBlackBlack
Cable length1.22 m1.22 m
Display typeKnown for oneLEDUnknown — not stated by the source
LED indicatorsDiffersBattery replacementYes
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-15 - 40 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 9000 m0 - 9000 m
Packaging contentidentical
ManualYesYes
Certificates1 differ
CertificationDiffersA-tick, C-tick, CE, IEC 62040-1-1, TelepermitA-tick, C-tick, CE, IEC 62040-1-1, RCM, TelePermit, REACH
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions1 differ
Width130 mm130 mm
Depth336 mm336 mm
Height215 mm215 mm
WeightDiffers12 kg8 kg
Packaging data1 differ
Bundled softwarePowerChute Personal EditionPowerChute Personal Edition
Package width245 mm245 mm
Package depth440 mm440 mm
Package height295 mm295 mm
Package weightDiffers12.9 kg8.99 kg
Logistics dataidentical
Harmonized System (HS) code8507800085078000
Other featuresidentical
Nominal input voltage230 V230 V
Nominal output voltage230 V230 V
Type of input protection required3-pole circuit breaker3-pole circuit breaker

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons