Key differences

  • Total power
    • E-PWS-704P-1R power supply unit:700 W
    • PWS-802A-1R power supply unit:800 W
  • Input current
    • E-PWS-704P-1R power supply unit:8.5 A
    • PWS-802A-1R power supply unit:5 - 10 A
  • Max output current (+12V)
    • E-PWS-704P-1R power supply unit:62 A
    • PWS-802A-1R power supply unit:66 A
  • Max output current (+5Vsb)
    • E-PWS-704P-1R power supply unit:3 A
    • PWS-802A-1R power supply unit:4 A
  • 80 PLUS certification
    • E-PWS-704P-1R power supply unit:80 PLUS Gold
    • PWS-802A-1R power supply unit:80 PLUS Titanium
  • Product colour
    • E-PWS-704P-1R power supply unit:Silver
    • PWS-802A-1R power supply unit:Grey
  • Width
    • E-PWS-704P-1R power supply unit:55 mm
    • PWS-802A-1R power supply unit:76 mm
  • Depth
    • E-PWS-704P-1R power supply unit:320 mm
    • PWS-802A-1R power supply unit:336 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of E-PWS-704P-1R, PWS-802A-1R
20 specifications
Power4 differ
Total powerDiffers700 W800 W
AC input voltage100 - 240 V100 - 240 V
Input currentDiffers8.5 A5 - 10 A
Power Factor Correction (PFC) typeKnown for oneUnknown — not stated by the sourceActive
Max output current (+12V)Differs62 A66 A
Max output current (+5Vsb)Differs3 A4 A
Performance1 differ
PurposeServerServer
Power supply unit (PSU) form factor1U1U
80 PLUS certificationDiffers80 PLUS Gold80 PLUS Titanium
Mean time between failures (MTBF)Known for oneUnknown — not stated by the source200000 h
Design1 differ
Product colourDiffersSilverGrey
Cooling typeKnown for oneActiveUnknown — not stated by the source
Number of fansKnown for one1 fan(s)Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions3 differ
WidthDiffers55 mm76 mm
DepthDiffers320 mm336 mm
Height40 mm40 mm
WeightDiffers400 g2.5 kg
Packaging data1 differ
Package weightDiffers500 g2.9 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source84733020