Product comparison · 2 power distribution units (pdus)

Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309 vs Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309 230/400V

Add a product
  • 20specifications compared
  • 3differ
  • 17identical
  • 0known for one product only

Key differences

AC outlets quantity: 24 AC outlet(s) on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309, 18 AC outlet(s) on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309 230/400V. Output connections: 18 x C13 & 6 x C19 on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309, 6 x C13 & 12 x C19 on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309 230/400V. Nominal input voltage: 230 V on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309, 230-400 V on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309 230/400V.

  • AC outlets quantity
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:24 AC outlet(s)
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309 230/400V:18 AC outlet(s)
  • Output connections
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:18 x C13 & 6 x C19
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309 230/400V:6 x C13 & 12 x C19
  • Nominal input voltage
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309:230 V
    • MPH2 Rack PDU, receptacle managed, 0U, input IEC 60309 230/400V:230-400 V

Side by side

Differences highlightedShow differences only (off)
Comparison of MPHR1143, MPHR1345
20 specifications
Designidentical
PDU typesMetered, SwitchedMetered, Switched
Rack capacity0U0U
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)18 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Output connectionsDiffers18 x C13 & 6 x C196 x C13 & 12 x C19
Featuresidentical
LED indicatorsYesYes
Management featuresidentical
Management platformWeb, CLI, SNMP, SSH, TelnetWeb, CLI, SNMP, SSH, Telnet
Power1 differ
Nominal input voltageDiffers230 V230-400 V
Maximum current32 A32 A
Power protection featuresOver currentOver current
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationUL, CSA, CE, REACH, FCC Class A, CB, WEEE, ISTAUL, CSA, CE, REACH, FCC Class A, CB, WEEE, ISTA
Operational conditionsidentical
Operating temperature (T-T)0 - 60 °C0 - 60 °C
Storage temperature (T-T)-25 - 85 °C-25 - 85 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Weight & dimensionsidentical
Width56 mm56 mm
Depth50 mm50 mm
Height1736.5 mm1736.5 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.