Product comparison · 2 power distribution units (pdus)

Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V vs Vertiv MPH2 Rack PDU, receptacle managed, 0U, input C19

Add a product
  • 19specifications compared
  • 6differ
  • 13identical
  • 0known for one product only

Key differences

The Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V has 16 A more maximum current than the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input C19 (32 A vs 16 A). The Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V has 822.5 mm more height than the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input C19 (1826.5 mm vs 1004 mm). PDU types: Basic on the Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V, Metered, Switched on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input C19. AC outlets quantity: 42 AC outlet(s) on the Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V, 16 AC outlet(s) on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input C19. Power plug: IEC 60309 on the Vertiv MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V, C20 coupler on the Vertiv MPH2 Rack PDU, receptacle managed, 0U, input C19.

  • PDU types
    • MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V:Basic
    • MPH2 Rack PDU, receptacle managed, 0U, input C19:Metered, Switched
  • AC outlets quantity
    • MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V:42 AC outlet(s)
    • MPH2 Rack PDU, receptacle managed, 0U, input C19:16 AC outlet(s)
  • Power plug
    • MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V:IEC 60309
    • MPH2 Rack PDU, receptacle managed, 0U, input C19:C20 coupler
  • Nominal input voltage
    • MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V:230-400 V
    • MPH2 Rack PDU, receptacle managed, 0U, input C19:230 V
  • Maximum current
    • MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V:32 A
    • MPH2 Rack PDU, receptacle managed, 0U, input C19:16 A
  • Height
    • MPH2 Rack PDU, branch metered, 0U, input IEC 60309 230/400V:1826.5 mm
    • MPH2 Rack PDU, receptacle managed, 0U, input C19:1004 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of MPHB1545, MPHR3141
19 specifications
Design1 differ
PDU typesDiffersBasicMetered, Switched
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)16 AC outlet(s)
Power plugDiffersIEC 60309C20 coupler
Power2 differ
Nominal input voltageDiffers230-400 V230 V
Maximum currentDiffers32 A16 A
Weight & dimensions1 differ
HeightDiffers1826.5 mm1004 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons