Product comparison · 2 power distribution units (pdus)

Vertiv Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black vs Vertiv Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black

Add a product
  • 26specifications compared
  • 8differ
  • 18identical
  • 1known for one product only

Key differences

The Vertiv Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black has 30 A more maximum current than the Vertiv Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black (60 A vs 30 A). The Vertiv Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black has 88 VA more load capacity than the Vertiv Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black (208 VA vs 120 VA). The Vertiv Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black has 43 mm more height than the Vertiv Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black (87 mm vs 44 mm). Type: Single-phase on the Vertiv Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black, Three-phase on the Vertiv Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black. Power plug: NEMA L5-30P on the Vertiv Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black, IEC 60309 on the Vertiv Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black.

  • Type
    • Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:Single-phase
    • Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:Three-phase
  • Power plug
    • Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:NEMA L5-30P
    • Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:IEC 60309
  • AC outlet types
    • Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:NEMA 5-20R
    • Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:C13 coupler, C19 coupler
  • Nominal input voltage
    • Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:100-120 V
    • Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:200-240 V
  • Maximum current
    • Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:30 A
    • Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:60 A
  • Load capacity
    • Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:120 VA
    • Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:208 VA
  • Height
    • Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:44 mm
    • Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:87 mm
  • Package weight
    • Geist MNU5M1R6-12S203-3TL5A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:5.44 kg
    • Geist MNU5MDR6-12CF18-6PS15D0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:9.07 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of MNU5M1R6-12S203-3TL5A0H10-S, MNU5MDR6-12CF18-6PS15D0H10-S
27 specifications
Design1 differ
TypeDiffersSingle-phaseThree-phase
Ports & interfaces2 differ
Power plugDiffersNEMA L5-30PIEC 60309
AC outlet typesDiffersNEMA 5-20RC13 coupler, C19 coupler
Power3 differ
Nominal input voltageDiffers100-120 V200-240 V
Maximum currentDiffers30 A60 A
Load capacityDiffers120 VA208 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Weight & dimensions1 differ
HeightDiffers44 mm87 mm
Packaging data1 differ
Package weightDiffers5.44 kg9.07 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons