Product comparison · 2 power distribution units (pdus)

Vertiv Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black vs Vertiv RPDU, SWITCHED UNIT LEVEL MONITORING EC

Add a product
  • 12specifications compared
  • 6differ
  • 6identical
  • 20known for one product only

Key differences

The Vertiv RPDU, SWITCHED UNIT LEVEL MONITORING EC has 1 U more rack capacity than the Vertiv Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black (1U vs 0U). The Vertiv Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black has 100 -240 V more nominal input voltage than the Vertiv RPDU, SWITCHED UNIT LEVEL MONITORING EC (200-240 V vs 100-240 V). The Vertiv Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black has 0.2 mm more width than the Vertiv RPDU, SWITCHED UNIT LEVEL MONITORING EC (432 mm vs 431.8 mm). AC input frequency: 50/60 Hz on the Vertiv Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black, 50 - 60 Hz on the Vertiv RPDU, SWITCHED UNIT LEVEL MONITORING EC.

  • Rack capacity
    • Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:0U
    • RPDU, SWITCHED UNIT LEVEL MONITORING EC:1U
  • Nominal input voltage
    • Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:200-240 V
    • RPDU, SWITCHED UNIT LEVEL MONITORING EC:100-240 V
  • AC input frequency
    • Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:50/60 Hz
    • RPDU, SWITCHED UNIT LEVEL MONITORING EC:50 - 60 Hz
  • Width
    • Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:432 mm
    • RPDU, SWITCHED UNIT LEVEL MONITORING EC:431.8 mm
  • Depth
    • Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:305 mm
    • RPDU, SWITCHED UNIT LEVEL MONITORING EC:304.8 mm
  • Height
    • Geist MNU3E1R6-12CF18-4CS15A0H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:44 mm
    • RPDU, SWITCHED UNIT LEVEL MONITORING EC:43.7 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of MNU3E1R6-12CF18-4CS15A0H10-S, RPDU, SWITCHED UNIT LEVEL MONITORING EC
32 specifications
Design1 differ
Rack capacityDiffers0U1U
DisplayKnown for oneLEDUnknown — not stated by the source
Ports & interfacesidentical
Serial ports quantityKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
USB ports quantityKnown for one1Unknown — not stated by the source
Featuresidentical
Reset buttonKnown for oneYesUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source3.048 m
Compatible productsKnown for oneUnknown — not stated by the sourceA2D-10 FS-15 GT3HD GTHD RDPS SRT-12
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Supported network protocolsKnown for oneDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPUnknown — not stated by the source
Power2 differ
Nominal input voltageDiffers200-240 V100-240 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentKnown for one35 AUnknown — not stated by the source
Load capacityKnown for one208 VAUnknown — not stated by the source
Power protection featuresKnown for oneOver currentUnknown — not stated by the source
Output voltageKnown for oneUnknown — not stated by the source100-240 V
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 60 °CUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers432 mm431.8 mm
DepthDiffers305 mm304.8 mm
HeightDiffers44 mm43.7 mm
WeightKnown for oneUnknown — not stated by the source4.54 kg
Packaging dataidentical
Package weightKnown for one8.16 kgUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationKnown for oneUnknown — not stated by the sourceUL & c-UL Listed 60950
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons