The Vertiv Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black has 10 A more maximum current than the Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black (30 A vs 20 A). The Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black has 43 mm more width than the Vertiv Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black (94 mm vs 51 mm). The Vertiv Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black has 1,617 mm more depth than the Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black (1683 mm vs 66 mm). AC outlets quantity: 48 AC outlet(s) on the Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black, 24 AC outlet(s) on the Vertiv Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black. Power plug: IEC 60309 on the Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black, NEMA L22-20P on the Vertiv Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black.

  • AC outlets quantity
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:48 AC outlet(s)
    • Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
  • Power plug
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:IEC 60309
    • Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:NEMA L22-20P
  • Nominal input voltage
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:200-240/346-415 V
    • Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:200-240 V
  • Maximum current
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:20 A
    • Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:30 A
  • Width
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:94 mm
    • Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:51 mm
  • Depth
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:66 mm
    • Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:1683 mm
  • Height
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:1778 mm
    • Geist MNU3EGB0-24PK33-2TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:66 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of MNS3EHW0-48PZB3-2PS56B0A10-S-A, MNU3EGB0-24PK33-2TL56A0A10-S-A
31 specifications
Designidentical
PDU typesSwitchedSwitched
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayLEDLED
On/off switchKnown for oneNoUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers48 AC outlet(s)24 AC outlet(s)
Power plugDiffersIEC 60309NEMA L22-20P
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Serial ports quantity11
Ethernet LAN (RJ-45) ports11
USB ports quantity11
Featuresidentical
Reset buttonYesYes
LED indicatorsYesYes
Cable length3 m3 m
Management featuresidentical
Supported network protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Power2 differ
Nominal input voltageDiffers200-240/346-415 V200-240 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers20 A30 A
Load capacityKnown for one230 VAUnknown — not stated by the source
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
CertificationDiffersRoHS Compliant FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Operational conditionsidentical
Operating temperature (T-T)0 - 60 °C0 - 60 °C
Weight & dimensions3 differ
WidthDiffers94 mm51 mm
DepthDiffers66 mm1683 mm
HeightDiffers1778 mm66 mm
WeightKnown for oneUnknown — not stated by the source8.16 kg
Packaging dataidentical
Package weightKnown for one8.16 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.