Product comparison · 2 power distribution units (pdus)

Vertiv Geist MNS3EGW2-36PT63-3PS56B0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black vs Vertiv Geist MNU3EGW2-36PNB3-3PS56B0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U

Add a product
  • 21specifications compared
  • 4differ
  • 17identical
  • 11known for one product only

Key differences

  • Nominal input voltage
    • Geist MNS3EGW2-36PT63-3PS56B0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:200-240/346-415 V
    • Geist MNU3EGW2-36PNB3-3PS56B0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U:200-240 V
  • Depth
    • Geist MNS3EGW2-36PT63-3PS56B0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:66 mm
    • Geist MNU3EGW2-36PNB3-3PS56B0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U:1829 mm
  • Height
    • Geist MNS3EGW2-36PT63-3PS56B0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:1829 mm
    • Geist MNU3EGW2-36PNB3-3PS56B0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U:66 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of MNS3EGW2-36PT63-3PS56B0A10-S-A, MNU3EGW2-36PNB3-3PS56B0A10-S-A
32 specifications
Designidentical
PDU typesSwitchedSwitched
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacity0U0U
MountingVerticalVertical
Product colourKnown for oneBlackUnknown — not stated by the source
DisplayLEDLED
On/off switchKnown for oneNoUnknown — not stated by the source
Ports & interfacesidentical
AC outlets quantity36 AC outlet(s)36 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Serial ports quantity11
Ethernet LAN (RJ-45) ports11
USB ports quantity11
Featuresidentical
LED indicatorsYesYes
Cable length3 m3 m
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Power1 differ
Nominal input voltageDiffers200-240/346-415 V200-240 V
AC input frequency50/60 Hz50/60 Hz
Maximum current30 A30 A
Load capacityKnown for one240 VAUnknown — not stated by the source
Number of phasesKnown for one3Unknown — not stated by the source
Power protection featuresOver currentOver current
Certificates1 differ
CertificationDiffersRoHS Compliant FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Operational conditionsidentical
Operating temperature (T-T)0 - 60 °C0 - 60 °C
Weight & dimensions2 differ
Width51 mm51 mm
DepthDiffers66 mm1829 mm
HeightDiffers1829 mm66 mm
WeightKnown for oneUnknown — not stated by the source9.98 kg
Packaging dataidentical
Package weightKnown for one9.98 kgUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons