Key differences

  • Type
    • Geist MNS3EGW1-36MBE9-3TL14A0A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:Single-phase
    • Geist MNU3EGB0-24CF13-2PS56B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:Three-phase
  • On/off switch
    • Geist MNS3EGW1-36MBE9-3TL14A0A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:Yes
    • Geist MNU3EGB0-24CF13-2PS56B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:No
  • AC outlets quantity
    • Geist MNS3EGW1-36MBE9-3TL14A0A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:36 AC outlet(s)
    • Geist MNU3EGB0-24CF13-2PS56B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
  • Power plug
    • Geist MNS3EGW1-36MBE9-3TL14A0A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:NEMA L14-30P
    • Geist MNU3EGB0-24CF13-2PS56B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:IEC 60309
  • Monitoring
    • Geist MNS3EGW1-36MBE9-3TL14A0A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:Current
    • Geist MNU3EGB0-24CF13-2PS56B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:Current, Power, Voltage
  • Nominal input voltage
    • Geist MNS3EGW1-36MBE9-3TL14A0A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:120/208 V
    • Geist MNU3EGB0-24CF13-2PS56B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:200-240/346-415 V
  • Maximum current
    • Geist MNS3EGW1-36MBE9-3TL14A0A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:30 A
    • Geist MNU3EGB0-24CF13-2PS56B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:20 A
  • Output voltage
    • Geist MNS3EGW1-36MBE9-3TL14A0A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:208 V
    • Geist MNU3EGB0-24CF13-2PS56B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:230 V

Side by side

Differences highlightedShow differences only (off)
Comparison of MNS3EGW1-36MBE9-3TL14A0A10-S, MNU3EGB0-24CF13-2PS56B0A10-S-A
29 specifications
Design2 differ
PDU typesSwitchedSwitched
TypeDiffersSingle-phaseThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayKnown for oneLEDUnknown — not stated by the source
On/off switchDiffersYesNo
Ports & interfaces3 differ
AC outlets quantityDiffers36 AC outlet(s)24 AC outlet(s)
Power plugDiffersNEMA L14-30PIEC 60309
AC outlet typesDiffersC13 coupler, C19 coupler, NEMA 5-20RC13 coupler, C19 coupler
Ethernet LAN (RJ-45) ports11
USB ports quantity11
Serial ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
LED indicatorsYesYes
Cable length3 m3 m
Management features1 differ
MonitoringDiffersCurrentCurrent, Power, Voltage
Supported network protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power4 differ
Nominal input voltageDiffers120/208 V200-240/346-415 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers30 A20 A
Output voltageDiffers208 V230 V
Load capacityDiffers208 VA230 VA
Power protection featuresKnown for oneOver currentUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 60 °CUnknown — not stated by the source
Weight & dimensions1 differ
Width51 mm51 mm
Depth66 mm66 mm
HeightDiffers1778 mm1683 mm
Packaging data1 differ
Package weightDiffers9.07 kg8.16 kg
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceRoHS Compliant FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1