Product comparison · 2 power distribution units (pdus)

Vertiv Geist MNR3EHW1-48MI18-5CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black vs Vertiv VSSBAN204-101R15 power distribution unit (PDU) 20 AC outlet(s) Black

Add a product
  • 17specifications compared
  • 13differ
  • 4identical
  • 7known for one product only

Key differences

  • On/off switch
    • Geist MNR3EHW1-48MI18-5CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:Yes
    • VSSBAN204-101R15 power distribution unit (PDU) 20 AC outlet(s) Black:No
  • AC outlets quantity
    • Geist MNR3EHW1-48MI18-5CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:36 AC outlet(s)
    • VSSBAN204-101R15 power distribution unit (PDU) 20 AC outlet(s) Black:20 AC outlet(s)
  • Power plug
    • Geist MNR3EHW1-48MI18-5CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:IEC 60309
    • VSSBAN204-101R15 power distribution unit (PDU) 20 AC outlet(s) Black:NEMA L5-15P
  • AC outlet types
    • Geist MNR3EHW1-48MI18-5CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:C13 coupler, C19 coupler
    • VSSBAN204-101R15 power distribution unit (PDU) 20 AC outlet(s) Black:NEMA 5-15R
  • Cable length
    • Geist MNR3EHW1-48MI18-5CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:3 m
    • VSSBAN204-101R15 power distribution unit (PDU) 20 AC outlet(s) Black:3.05 m
  • Nominal input voltage
    • Geist MNR3EHW1-48MI18-5CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:200-240/346-415 V
    • VSSBAN204-101R15 power distribution unit (PDU) 20 AC outlet(s) Black:100-120 V
  • Maximum current
    • Geist MNR3EHW1-48MI18-5CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:20 A
    • VSSBAN204-101R15 power distribution unit (PDU) 20 AC outlet(s) Black:15 A
  • Load capacity
    • Geist MNR3EHW1-48MI18-5CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:230 VA
    • VSSBAN204-101R15 power distribution unit (PDU) 20 AC outlet(s) Black:120 VA

Side by side

Differences highlightedShow differences only (on)
Comparison of MNR3EHW1-48MI18-5CS15A0A10-S-A, VSSBAN204-101R15
24 specifications
Design1 differ
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityKnown for one0UUnknown — not stated by the source
On/off switchDiffersYesNo
Ports & interfaces3 differ
AC outlets quantityDiffers36 AC outlet(s)20 AC outlet(s)
Power plugDiffersIEC 60309NEMA L5-15P
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5-15R
Features1 differ
Cable lengthDiffers3 m3.05 m
LED indicatorsKnown for oneUnknown — not stated by the sourcePower
Power3 differ
Nominal input voltageDiffers200-240/346-415 V100-120 V
Maximum currentDiffers20 A15 A
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers230 VA120 VA
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
CertificationDiffersRoHS Compliant FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1RoHS Compliant UL & c-UL Listed 60950
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 60 °C10 - 45 °C
Weight & dimensions3 differ
WidthDiffers51 mm41 mm
DepthDiffers51 mm41 mm
HeightDiffers1683 mm1682.8 mm
WeightKnown for oneUnknown — not stated by the source4.08 kg
Packaging dataidentical
Package weightKnown for one7.26 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons