The Vertiv Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black has 40 A more maximum current than the Vertiv Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black (60 A vs 20 A). The Vertiv Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black has 11,500 W more maximum power than the Vertiv Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black (17200 W vs 5700 W). The Vertiv Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black has 45 mm more depth than the Vertiv Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black (95 mm vs 50 mm). AC outlets quantity: 42 AC outlet(s) on the Vertiv Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black, 48 AC outlet(s) on the Vertiv Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black. Nominal input voltage: 100-120/200-240V WYE on the Vertiv Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black, 200-240V Delta on the Vertiv Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black.

  • AC outlets quantity
    • Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black:42 AC outlet(s)
    • Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black:48 AC outlet(s)
  • Nominal input voltage
    • Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black:100-120/200-240V WYE
    • Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black:200-240V Delta
  • Maximum current
    • Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black:20 A
    • Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black:60 A
  • Maximum power
    • Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black:5700 W
    • Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black:17200 W
  • Depth
    • Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black:50 mm
    • Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black:95 mm
  • Height
    • Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black:50 mm
    • Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black:87 mm
  • Package weight
    • Geist MN05M4W0-42PZ68-2TL21A0A10-S power distribution unit (PDU) 42 AC outlet(s) Black:7.26 kg
    • Geist MN05M9W1-48PZB8-6PS15B0A10-S power distribution unit (PDU) 48 AC outlet(s) Black:14.5 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of MN05M4W0-42PZ68-2TL21A0A10-S, MN05M9W1-48PZB8-6PS15B0A10-S
32 specifications
Designidentical
PDU typesMonitoredMonitored
TypeThree-phaseThree-phase
MountingVerticalVertical
Product colourBlackBlack
DisplayLEDLED
Ports & interfaces1 differ
AC outlets quantityDiffers42 AC outlet(s)48 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler
Ethernet LAN (RJ-45) ports22
USB ports quantity11
Featuresidentical
Daisy chainYesYes
Reset buttonYesYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable length3 m3 m
Management featuresidentical
MonitoringCurrent, Power, Temperature, VoltageCurrent, Power, Temperature, Voltage
Supported network protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers100-120/200-240V WYE200-240V Delta
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers20 A60 A
Output voltage208 V208 V
Maximum powerDiffers5700 W17200 W
Circuit breakerYesYes
Power protection featuresKnown for oneOver currentUnknown — not stated by the source
Certificatesidentical
Compliance certificatesFederal Communications Commission (FCC), RoHS, ULFederal Communications Commission (FCC), RoHS, UL
CertificationKnown for oneRoHS Compliant FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1Unknown — not stated by the source
Sustainabilityidentical
Sustainability complianceYesYes
Weight & dimensions2 differ
Width1828 mm1828 mm
DepthDiffers50 mm95 mm
HeightDiffers50 mm87 mm
Packaging contentidentical
Rack mount kitYesYes
Packaging data1 differ
Package weightDiffers7.26 kg14.5 kg
Logistics dataidentical
Warranty period5 year(s)5 year(s)