Product comparison · 2 power distribution units (pdus)

Vertiv Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black vs Vertiv Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black

Add a product
  • 31specifications compared
  • 8differ
  • 23identical
  • 1known for one product only

Key differences

The Vertiv Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black has 10 A more maximum current than the Vertiv Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black (30 A vs 20 A). The Vertiv Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black has 2,900 W more maximum power than the Vertiv Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black (8600 W vs 5700 W). The Vertiv Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black has 77 mm more width than the Vertiv Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black (1905 mm vs 1828 mm). AC outlets quantity: 41 AC outlet(s) on the Vertiv Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black, 44 AC outlet(s) on the Vertiv Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black. Power plug: NEMA L21-20P on the Vertiv Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black, NEMA L21-30P on the Vertiv Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black.

  • AC outlets quantity
    • Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black:41 AC outlet(s)
    • Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black:44 AC outlet(s)
  • Power plug
    • Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black:NEMA L21-20P
    • Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black:NEMA L21-30P
  • Maximum current
    • Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black:20 A
    • Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black:30 A
  • Maximum power
    • Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black:5700 W
    • Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black:8600 W
  • Width
    • Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black:1828 mm
    • Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black:1905 mm
  • Depth
    • Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black:50 mm
    • Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black:88 mm
  • Package weight
    • Geist MN05M4W0-41ML59-2TL21A0A10-S power distribution unit (PDU) 41 AC outlet(s) Black:7.26 kg
    • Geist MN05M5W1-44MJ89-3TL21A0A10-S-A power distribution unit (PDU) 44 AC outlet(s) Black:8.62 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of MN05M4W0-41ML59-2TL21A0A10-S, MN05M5W1-44MJ89-3TL21A0A10-S-A
32 specifications
Ports & interfaces2 differ
AC outlets quantityDiffers41 AC outlet(s)44 AC outlet(s)
Power plugDiffersNEMA L21-20PNEMA L21-30P
Management features1 differ
MonitoringDiffersCurrent, Power, VoltageCurrent, Power, Temperature, Voltage
Power2 differ
Maximum currentDiffers20 A30 A
Maximum powerDiffers5700 W8600 W
Power protection featuresKnown for oneOver currentUnknown — not stated by the source
Weight & dimensions2 differ
WidthDiffers1828 mm1905 mm
DepthDiffers50 mm88 mm
Packaging data1 differ
Package weightDiffers7.26 kg8.62 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.