Product comparison · 2 power distribution units (pdus)

Vertiv MGR5MGB0-24CF13-2PS56B2A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black vs Vertiv Geist MGS5MGW1-36PT63-3PS6B2A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black

Add a product
  • 20specifications compared
  • 8differ
  • 12identical
  • 12known for one product only

Key differences

  • PDU types
    • MGR5MGB0-24CF13-2PS56B2A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:Monitored
    • Geist MGS5MGW1-36PT63-3PS6B2A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:Monitored, Switched
  • Type
    • MGR5MGB0-24CF13-2PS56B2A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:Three-phase
    • Geist MGS5MGW1-36PT63-3PS6B2A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:Single-phase
  • AC outlets quantity
    • MGR5MGB0-24CF13-2PS56B2A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
    • Geist MGS5MGW1-36PT63-3PS6B2A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:36 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • MGR5MGB0-24CF13-2PS56B2A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:2
    • Geist MGS5MGW1-36PT63-3PS6B2A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:1
  • Nominal input voltage
    • MGR5MGB0-24CF13-2PS56B2A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:200 - 415 V
    • Geist MGS5MGW1-36PT63-3PS6B2A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:200-240 V
  • Maximum current
    • MGR5MGB0-24CF13-2PS56B2A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:16 A
    • Geist MGS5MGW1-36PT63-3PS6B2A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:32 A
  • Load capacity
    • MGR5MGB0-24CF13-2PS56B2A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:11000 VA
    • Geist MGS5MGW1-36PT63-3PS6B2A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:230 VA
  • Height
    • MGR5MGB0-24CF13-2PS56B2A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:1683 mm
    • Geist MGS5MGW1-36PT63-3PS6B2A10-S power distribution unit (PDU) 36 AC outlet(s) 0U Black:1778 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of MGR5MGB0-24CF13-2PS56B2A10-S-A, MGS5MGW1-36PT63-3PS6B2A10-S
32 specifications
Design2 differ
PDU typesDiffersMonitoredMonitored, Switched
TypeDiffersThree-phaseSingle-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayLCDLCD
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)36 AC outlet(s)
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsDiffers21
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Daisy chainKnown for oneYesUnknown — not stated by the source
Reset buttonKnown for oneYesUnknown — not stated by the source
Cable length3 m3 m
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Supported network protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers200 - 415 V200-240 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A32 A
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers11000 VA230 VA
Maximum powerKnown for one11000 WUnknown — not stated by the source
Power protection featuresOver currentOver current
Certificatesidentical
Compliance certificatesKnown for oneCE, UKCA, RoHS, RCM, China RoHSUnknown — not stated by the source
Weight & dimensions1 differ
Width51 mm51 mm
Depth66 mm66 mm
HeightDiffers1683 mm1778 mm
WeightKnown for one8.16 kgUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 60 °C
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source9.07 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.