Product comparison · 2 power distribution units (pdus)

Vertiv Geist MG05M1R0-10L133-2PS6B2H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black vs Vertiv Geist MGR5M1R6-12CF13-3PS56B2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black

Add a product
  • 25specifications compared
  • 7differ
  • 18identical
  • 1known for one product only

Key differences

  • Type
    • Geist MG05M1R0-10L133-2PS6B2H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:Single-phase
    • Geist MGR5M1R6-12CF13-3PS56B2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:Three-phase
  • AC outlets quantity
    • Geist MG05M1R0-10L133-2PS6B2H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:10 AC outlet(s)
    • Geist MGR5M1R6-12CF13-3PS56B2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:12 AC outlet(s)
  • AC outlet types
    • Geist MG05M1R0-10L133-2PS6B2H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:C13 coupler
    • Geist MGR5M1R6-12CF13-3PS56B2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:C13 coupler, C19 coupler
  • Nominal input voltage
    • Geist MG05M1R0-10L133-2PS6B2H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:200-240 V
    • Geist MGR5M1R6-12CF13-3PS56B2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:200-240/346-415 V
  • Maximum current
    • Geist MG05M1R0-10L133-2PS6B2H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:16 A
    • Geist MGR5M1R6-12CF13-3PS56B2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:32 A
  • Depth
    • Geist MG05M1R0-10L133-2PS6B2H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:216 mm
    • Geist MGR5M1R6-12CF13-3PS56B2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:305 mm
  • Package weight
    • Geist MG05M1R0-10L133-2PS6B2H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:5.44 kg
    • Geist MGR5M1R6-12CF13-3PS56B2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:8.16 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of MG05M1R0-10L133-2PS6B2H10-S, MGR5M1R6-12CF13-3PS56B2H10-S
26 specifications
Design1 differ
PDU typesMonitoredMonitored
TypeDiffersSingle-phaseThree-phase
Rack capacity0U0U
MountingHorizontalHorizontal
Product colourBlackBlack
DisplayLEDLED
Ports & interfaces2 differ
AC outlets quantityDiffers10 AC outlet(s)12 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Serial ports quantity11
Ethernet LAN (RJ-45) ports11
USB ports quantity11
Featuresidentical
Reset buttonYesYes
Cable length3 m3 m
Management featuresidentical
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Supported network protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power2 differ
Nominal input voltageDiffers200-240 V200-240/346-415 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A32 A
Load capacity230 VA230 VA
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Operational conditionsidentical
Operating temperature (T-T)0 - 60 °C0 - 60 °C
Weight & dimensions1 differ
Width432 mm432 mm
DepthDiffers216 mm305 mm
Height44 mm44 mm
Packaging data1 differ
Package weightDiffers5.44 kg8.16 kg