Product comparison · 2 power distribution units (pdus)

Vertiv MG01D4B0-30PN63-2PS56B2A10-S-A power distribution unit (PDU) 30 AC outlet(s) 0U Black vs Vertiv MG01X2R1-16PB43-3PS6C2H10-S power distribution unit (PDU) 16 AC outlet(s) 2U Black

Add a product
  • 19specifications compared
  • 11differ
  • 8identical
  • 6known for one product only

Key differences

  • PDU types
    • MG01D4B0-30PN63-2PS56B2A10-S-A power distribution unit (PDU) 30 AC outlet(s) 0U Black:Metered
    • MG01X2R1-16PB43-3PS6C2H10-S power distribution unit (PDU) 16 AC outlet(s) 2U Black:Basic
  • Rack capacity
    • MG01D4B0-30PN63-2PS56B2A10-S-A power distribution unit (PDU) 30 AC outlet(s) 0U Black:0U
    • MG01X2R1-16PB43-3PS6C2H10-S power distribution unit (PDU) 16 AC outlet(s) 2U Black:2U
  • Mounting
    • MG01D4B0-30PN63-2PS56B2A10-S-A power distribution unit (PDU) 30 AC outlet(s) 0U Black:Vertical
    • MG01X2R1-16PB43-3PS6C2H10-S power distribution unit (PDU) 16 AC outlet(s) 2U Black:Horizontal
  • AC outlets quantity
    • MG01D4B0-30PN63-2PS56B2A10-S-A power distribution unit (PDU) 30 AC outlet(s) 0U Black:30 AC outlet(s)
    • MG01X2R1-16PB43-3PS6C2H10-S power distribution unit (PDU) 16 AC outlet(s) 2U Black:16 AC outlet(s)
  • Power plug
    • MG01D4B0-30PN63-2PS56B2A10-S-A power distribution unit (PDU) 30 AC outlet(s) 0U Black:IEC 60309
    • MG01X2R1-16PB43-3PS6C2H10-S power distribution unit (PDU) 16 AC outlet(s) 2U Black:Type I
  • Nominal input voltage
    • MG01D4B0-30PN63-2PS56B2A10-S-A power distribution unit (PDU) 30 AC outlet(s) 0U Black:200 - 415 V
    • MG01X2R1-16PB43-3PS6C2H10-S power distribution unit (PDU) 16 AC outlet(s) 2U Black:200 - 240 V
  • Maximum current
    • MG01D4B0-30PN63-2PS56B2A10-S-A power distribution unit (PDU) 30 AC outlet(s) 0U Black:16 A
    • MG01X2R1-16PB43-3PS6C2H10-S power distribution unit (PDU) 16 AC outlet(s) 2U Black:32 A
  • Maximum power
    • MG01D4B0-30PN63-2PS56B2A10-S-A power distribution unit (PDU) 30 AC outlet(s) 0U Black:11000 W
    • MG01X2R1-16PB43-3PS6C2H10-S power distribution unit (PDU) 16 AC outlet(s) 2U Black:7300 W

Side by side

Differences highlightedShow differences only (off)
Comparison of MG01D4B0-30PN63-2PS56B2A10-S-A, MG01X2R1-16PB43-3PS6C2H10-S
25 specifications
Design3 differ
PDU typesDiffersMeteredBasic
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
DisplayKnown for oneLEDUnknown — not stated by the source
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers30 AC outlet(s)16 AC outlet(s)
Power plugDiffersIEC 60309Type I
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Featuresidentical
Colour-coded outletsYesYes
Cable length3 m3 m
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers200 - 415 V200 - 240 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers16 A32 A
Output voltage230 V230 V
Maximum powerDiffers11000 W7300 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificatesidentical
Compliance certificatesRoHSRoHS
Weight & dimensions3 differ
WidthDiffers51 mm432 mm
DepthDiffers51 mm229 mm
HeightDiffers1683 mm87 mm
Weight6.8 kg6.8 kg
Size (imperial)Known for oneUnknown — not stated by the source48.3 cm (19")

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.