Vertiv Geist UR30001L vs Vertiv Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black

Add a product
  • 20specifications compared
  • 12differ
  • 8identical
  • 15known for one product only

Key differences

The Vertiv Geist UR30001L has 1 more serial ports quantity than the Vertiv Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black (2 vs 1). The Vertiv Geist UR30001L has 1 more Ethernet LAN (RJ-45) ports than the Vertiv Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black (2 vs 1). The Vertiv Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black has 10 A more maximum current than the Vertiv Geist UR30001L (30 A vs 20 A). PDU types: Monitored on the Vertiv Geist UR30001L, Switched on the Vertiv Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black. Power plug: C20 coupler on the Vertiv Geist UR30001L, NEMA L22-30P on the Vertiv Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black.

  • PDU types
    • Geist UR30001L:Monitored
    • Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:Switched
  • Power plug
    • Geist UR30001L:C20 coupler
    • Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:NEMA L22-30P
  • AC outlet types
    • Geist UR30001L:C13 coupler
    • Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:C13 coupler, C19 coupler
  • Serial ports quantity
    • Geist UR30001L:2
    • Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:1
  • Ethernet LAN (RJ-45) ports
    • Geist UR30001L:2
    • Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:1
  • Nominal input voltage
    • Geist UR30001L:100-240 V
    • Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:200-240/346-415 V
  • AC input frequency
    • Geist UR30001L:50 - 60 Hz
    • Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:50/60 Hz
  • Maximum current
    • Geist UR30001L:20 A
    • Geist MNU3EGB1-24PBB3-3TL56A0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:30 A

Side by side

Differences highlightedShow differences only (off)
Comparison of Geist UR30001L, MNU3EGB1-24PBB3-3TL56A0A10-S-A
35 specifications
Design1 differ
PDU typesDiffersMonitoredSwitched
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayLEDLED
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces4 differ
AC outlets quantity24 AC outlet(s)24 AC outlet(s)
Power plugDiffersC20 couplerNEMA L22-30P
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Serial ports quantityDiffers21
Ethernet LAN (RJ-45) portsDiffers21
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Reset buttonYesYes
LED indicatorsYesYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Daisy chainKnown for oneYesUnknown — not stated by the source
Management features1 differ
Supported network protocolsDiffersDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers100-240 V200-240/346-415 V
AC input frequencyDiffers50 - 60 Hz50/60 Hz
Maximum currentDiffers20 A30 A
Load capacityKnown for oneUnknown — not stated by the source230 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Nominal output voltageKnown for one100-240 VUnknown — not stated by the source
Maximum powerKnown for one3600 WUnknown — not stated by the source
Certificates1 differ
CertificationDiffersCE, EN55032, EN55024, IEC 60950-1, RCM, UL, c-ULRoHS Compliant FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 60 °C
Weight & dimensions2 differ
WidthDiffers1683 mm51 mm
Depth66 mm66 mm
HeightDiffers51 mm1683 mm
WeightKnown for one8.16 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source9.98 kg