Product comparison · 2 power distribution units (pdus)

Vertiv Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19 vs Vertiv GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13

Add a product
  • 26specifications compared
  • 14differ
  • 12identical
  • 2known for one product only

Key differences

The Vertiv Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19 has 16 A more maximum current than the Vertiv GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13 (32 A vs 16 A). The Vertiv Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19 has 3,700 VA more load capacity than the Vertiv GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13 (7300 VA vs 3600 VA). The Vertiv Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19 has 95 mm more width than the Vertiv GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13 (1778 mm vs 1683 mm). Only the Vertiv GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13 has LED indicators. PDU types: Monitored on the Vertiv Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19, Switched on the Vertiv GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13.

  • PDU types
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:Monitored
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:Switched
  • AC outlets quantity
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:42 AC outlet(s)
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:24 AC outlet(s)
  • Power plug
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:IEC 60309
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:C20 coupler
  • Output connections
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:36 x C13 & 6 x C19
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:21 x C13 & 3 x C19
  • LED indicators
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:No
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:Yes
  • Maximum current
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:32 A
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:16 A
  • Load capacity
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:7300 VA
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:3600 VA
  • Operating temperature (T-T)
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:0 - 60 °C
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:0 - 50 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19, GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13
28 specifications
Design1 differ
PDU typesDiffersMonitoredSwitched
TypeSingle-phaseSingle-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)24 AC outlet(s)
Power plugDiffersIEC 60309C20 coupler
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Output connectionsDiffers36 x C13 & 6 x C1921 x C13 & 3 x C19
Features1 differ
LED indicatorsDiffersNoYes
Cable lengthKnown for one3 mUnknown — not stated by the source
Management features1 differ
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Management platformDiffersWeb UI, HTTP, HTTPS (TLS 1.2), SMTP, SMTPS (TLS 1.2), ICMP, DHCP, IPv4, IPv6, Syslog, SNMP v1/v2c/v3, JSON, JSON, API, RSTPWeb UI, DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RSTP, SSH, SNMP (v1/v2c/v3), Syslog, CSV datalog, JSON API, JSON datalog
Power2 differ
Nominal input voltage230 V230 V
AC input frequency50 Hz50 Hz
Maximum currentDiffers32 A16 A
Load capacityDiffers7300 VA3600 VA
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersCE, RoHS, CBCE, RoHS, CB certificate, FCC Part 15 class A, UL, c-UL
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 60 °C0 - 50 °C
Weight & dimensions3 differ
WidthDiffers1778 mm1683 mm
Depth51 mm51 mm
HeightDiffers51 mm66 mm
WeightDiffers6.2 kg8.16 kg
Packaging data1 differ
Package weightKnown for one7.26 kgUnknown — not stated by the source
Package widthDiffers2172 mm1829 mm
Package depth223 mm223 mm
Package height159 mm159 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.