Product comparison · 2 power distribution units (pdus)

Vertiv Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19 vs Vertiv Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19

Add a product
  • 27specifications compared
  • 14differ
  • 13identical
  • 0known for one product only

Key differences

The Vertiv Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19 has 14,700 VA more load capacity than the Vertiv Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19 (22000 VA vs 7300 VA). The Vertiv Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19 has 146 mm more width than the Vertiv Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19 (1829 mm vs 1683 mm). The Vertiv Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19 has 8 mm more height than the Vertiv Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19 (66 mm vs 58 mm). Only the Vertiv Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19 has LED indicators. PDU types: Monitored on the Vertiv Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19, Switched on the Vertiv Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19.

  • PDU types
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19:Monitored
    • Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19:Switched
  • Type
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19:Three-phase
    • Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19:Single-phase
  • AC outlets quantity
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19:42 AC outlet(s)
    • Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19:24 AC outlet(s)
  • Output connections
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19:30 x C13 & 12 x C19
    • Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19:20 x C13 & 4 x C19
  • LED indicators
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19:No
    • Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19:Yes
  • Nominal input voltage
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19:230/400 V
    • Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19:230 V
  • Load capacity
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19:22000 VA
    • Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19:7300 VA
  • Operating temperature (T-T)
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19:0 - 60 °C
    • Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19:0 - 50 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19, Geist rPDU, switched, 0U, input IEC60309 230V 32A, outputs (20)C13 | (4)C19
27 specifications
Design2 differ
PDU typesDiffersMonitoredSwitched
TypeDiffersThree-phaseSingle-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)24 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Output connectionsDiffers30 x C13 & 12 x C1920 x C13 & 4 x C19
Features1 differ
LED indicatorsDiffersNoYes
Cable length3 m3 m
Management features1 differ
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Management platformDiffersWeb UI, HTTP, HTTPS (TLS 1.2), SMTP, SMTPS (TLS 1.2), ICMP, DHCP, IPv4, IPv6, Syslog, SNMP v1/v2c/v3, JSON, JSON, API, RSTPWeb UI, DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RSTP, SSH, SMTP, (v1/v2c/v3), Syslog, CSV datalog, JSON API, JSON datalog
Power2 differ
Nominal input voltageDiffers230/400 V230 V
AC input frequency50 Hz50 Hz
Maximum current32 A32 A
Load capacityDiffers22000 VA7300 VA
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersCE, RoHS, CB certificateCE, RoHS, CB certificate, FCC Part 15 class A, UL, c-UL
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 60 °C0 - 50 °C
Weight & dimensions3 differ
WidthDiffers1829 mm1683 mm
Depth51 mm51 mm
HeightDiffers58 mm66 mm
WeightDiffers7.71 kg9.07 kg
Packaging data1 differ
Package widthDiffers2172 mm18 mm
Package depth223 mm223 mm
Package height159 mm159 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.