Product comparison · 2 power distribution units (pdus)

Vertiv Geist rPDU, basic, 0U, input IEC60309 230V 16A, outputs (20)C13 | (4)C19 vs Vertiv Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19

Add a product
  • 24specifications compared
  • 9differ
  • 15identical
  • 3known for one product only

Key differences

  • PDU types
    • Geist rPDU, basic, 0U, input IEC60309 230V 16A, outputs (20)C13 | (4)C19:Basic
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:Monitored
  • AC outlets quantity
    • Geist rPDU, basic, 0U, input IEC60309 230V 16A, outputs (20)C13 | (4)C19:24 AC outlet(s)
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:20 AC outlet(s)
  • Power plug
    • Geist rPDU, basic, 0U, input IEC60309 230V 16A, outputs (20)C13 | (4)C19:IEC 60309
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:C20 coupler
  • Output connections
    • Geist rPDU, basic, 0U, input IEC60309 230V 16A, outputs (20)C13 | (4)C19:20 x C13 & 4 x C19
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:18 x C13 & 2 x C19
  • Certification
    • Geist rPDU, basic, 0U, input IEC60309 230V 16A, outputs (20)C13 | (4)C19:CE, RoHS, CB
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:CE, RoHS, CB certificate
  • Operating temperature (T-T)
    • Geist rPDU, basic, 0U, input IEC60309 230V 16A, outputs (20)C13 | (4)C19:0 - 45 °C
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:0 - 60 °C
  • Width
    • Geist rPDU, basic, 0U, input IEC60309 230V 16A, outputs (20)C13 | (4)C19:978 mm
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:914 mm
  • Weight
    • Geist rPDU, basic, 0U, input IEC60309 230V 16A, outputs (20)C13 | (4)C19:3.5 kg
    • Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19:4.54 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of Geist rPDU, basic, 0U, input IEC60309 230V 16A, outputs (20)C13 | (4)C19, Geist rPDU, monitored, 0U, input C20 230V 16A, outputs (18)C13 | (2)C19
27 specifications
Design1 differ
PDU typesDiffersBasicMonitored
TypeSingle-phaseSingle-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers24 AC outlet(s)20 AC outlet(s)
Power plugDiffersIEC 60309C20 coupler
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Output connectionsDiffers20 x C13 & 4 x C1918 x C13 & 2 x C19
Featuresidentical
LED indicatorsNoNo
Cable lengthKnown for one3 mUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Management platformKnown for oneUnknown — not stated by the sourceWeb UI, HTTP, HTTPS (TLS 1.2), SMTP, SMTPS (TLS 1.2), ICMP, DHCP, IPv4, IPv6, Syslog, SNMP v1/v2c/v3, JSON, JSON, API, RSTP
Poweridentical
Nominal input voltage230 V230 V
AC input frequency50 Hz50 Hz
Maximum current16 A16 A
Load capacity3600 VA3600 VA
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersCE, RoHS, CBCE, RoHS, CB certificate
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 45 °C0 - 60 °C
Weight & dimensions2 differ
WidthDiffers978 mm914 mm
Depth51 mm51 mm
Height51 mm51 mm
WeightDiffers3.5 kg4.54 kg
Packaging data1 differ
Package widthDiffers1270 mm1042 mm
Package depth127 mm127 mm
Package height77 mm77 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.