Product comparison · 2 power distribution units (pdus)

Vertiv Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19 vs Vertiv GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13

Add a product
  • 23specifications compared
  • 12differ
  • 11identical
  • 6known for one product only

Key differences

  • PDU types
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:Basic
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:Switched
  • Type
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:Three-phase
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:Single-phase
  • AC outlets quantity
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:42 AC outlet(s)
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:24 AC outlet(s)
  • Power plug
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:IEC 60309
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:C20 coupler
  • Output connections
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:36 x C13 & 6 x C19
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:21 x C13 & 3 x C19
  • LED indicators
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:No
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:Yes
  • Nominal input voltage
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:230/400 V
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:230 V
  • Load capacity
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:11000 VA
    • GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13:3600 VA

Side by side

Differences highlightedShow differences only (on)
Comparison of Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19, GEIST RPDU SWITCHED 0U INPC20 230V 16A OUTP (21)C13
29 specifications
Design2 differ
PDU typesDiffersBasicSwitched
TypeDiffersThree-phaseSingle-phase
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)24 AC outlet(s)
Power plugDiffersIEC 60309C20 coupler
Output connectionsDiffers36 x C13 & 6 x C1921 x C13 & 3 x C19
Features1 differ
LED indicatorsDiffersNoYes
Cable lengthKnown for one3 mUnknown — not stated by the source
Power2 differ
Nominal input voltageDiffers230/400 V230 V
Load capacityDiffers11000 VA3600 VA
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum currentKnown for oneUnknown — not stated by the source16 A
Certificates1 differ
CertificationDiffersCE, RoHS, CBCE, RoHS, CB certificate, FCC Part 15 class A, UL, c-UL
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 45 °C0 - 50 °C
Weight & dimensions2 differ
HeightDiffers51 mm66 mm
WeightDiffers6.6 kg8.16 kg
Packaging dataidentical
Package weightKnown for one7.71 kgUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Management platformKnown for oneUnknown — not stated by the sourceWeb UI, DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RSTP, SSH, SNMP (v1/v2c/v3), Syslog, CSV datalog, JSON API, JSON datalog