Product comparison · 2 power distribution units (pdus)

Vertiv Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19 vs Vertiv Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19

Add a product
  • 25specifications compared
  • 9differ
  • 16identical
  • 4known for one product only

Key differences

  • PDU types
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:Basic
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:Monitored
  • Type
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:Three-phase
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:Single-phase
  • Nominal input voltage
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:230/400 V
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:230 V
  • Load capacity
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:11000 VA
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:7300 VA
  • Operating temperature (T-T)
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:0 - 45 °C
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:0 - 60 °C
  • Width
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:1683 mm
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:1778 mm
  • Weight
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:6.6 kg
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:6.2 kg
  • Package weight
    • Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:7.71 kg
    • Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19:7.26 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of Geist rPDU, basic, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19, Geist rPDU, monitored, 0U, input IEC60309 230V 32A, outputs (36)C13 | (6)C19
29 specifications
Design2 differ
PDU typesDiffersBasicMonitored
TypeDiffersThree-phaseSingle-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfacesidentical
AC outlets quantity42 AC outlet(s)42 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Output connections36 x C13 & 6 x C1936 x C13 & 6 x C19
Featuresidentical
LED indicatorsNoNo
Cable length3 m3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Management platformKnown for oneUnknown — not stated by the sourceWeb UI, HTTP, HTTPS (TLS 1.2), SMTP, SMTPS (TLS 1.2), ICMP, DHCP, IPv4, IPv6, Syslog, SNMP v1/v2c/v3, JSON, JSON, API, RSTP
Power2 differ
Nominal input voltageDiffers230/400 V230 V
AC input frequency50 Hz50 Hz
Maximum currentKnown for oneUnknown — not stated by the source32 A
Load capacityDiffers11000 VA7300 VA
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationCE, RoHS, CBCE, RoHS, CB
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 45 °C0 - 60 °C
Weight & dimensions2 differ
WidthDiffers1683 mm1778 mm
Depth51 mm51 mm
Height51 mm51 mm
WeightDiffers6.6 kg6.2 kg
Packaging data2 differ
Package weightDiffers7.71 kg7.26 kg
Package widthDiffers1829 mm2172 mm
Package depth223 mm223 mm
Package height159 mm159 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.