Product comparison · 2 power distribution units (pdus)

Vertiv Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black vs Vertiv Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black

Add a product
  • 23specifications compared
  • 7differ
  • 16identical
  • 3known for one product only

Key differences

The Vertiv Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black has 28 A more maximum current than the Vertiv Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black (48 A vs 20 A). The Vertiv Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black has 89 mm more depth than the Vertiv Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black (305 mm vs 216 mm). PDU types: Monitored, Switched on the Vertiv Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black, Monitored on the Vertiv Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black. Display: LCD on the Vertiv Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black, LED on the Vertiv Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black. AC outlets quantity: 12 AC outlet(s) on the Vertiv Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black, 10 AC outlet(s) on the Vertiv Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black.

  • PDU types
    • Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:Monitored, Switched
    • Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:Monitored
  • Display
    • Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:LCD
    • Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:LED
  • AC outlets quantity
    • Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:12 AC outlet(s)
    • Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:10 AC outlet(s)
  • AC outlet types
    • Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:C13 coupler, C19 coupler
    • Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:NEMA 5-20R
  • Nominal input voltage
    • Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:240/415 V
    • Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:100-120 V
  • Maximum current
    • Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:48 A
    • Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:20 A
  • Depth
    • Geist DUU5M1R6-12CF17-1S02A0H00-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:305 mm
    • Geist MN05M1R0-10D203-2TL5A0H10-S power distribution unit (PDU) 10 AC outlet(s) 0U Black:216 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of DUU5M1R6-12CF17-1S02A0H00-S, MN05M1R0-10D203-2TL5A0H10-S
26 specifications
Design2 differ
PDU typesDiffersMonitored, SwitchedMonitored
TypeSingle-phaseSingle-phase
Rack capacity0U0U
MountingHorizontalHorizontal
Product colourBlackBlack
DisplayDiffersLCDLED
Ports & interfaces2 differ
AC outlets quantityDiffers12 AC outlet(s)10 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceNEMA L5-20P
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5-20R
Serial ports quantity11
Ethernet LAN (RJ-45) ports11
USB ports quantity11
Featuresidentical
Cable length3 m3 m
LED indicatorsKnown for oneYesUnknown — not stated by the source
Management featuresidentical
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Supported network protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power2 differ
Nominal input voltageDiffers240/415 V100-120 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers48 A20 A
Load capacityKnown for oneUnknown — not stated by the source120 VA
Power protection featuresOver currentOver current
Operational conditionsidentical
Operating temperature (T-T)0 - 60 °C0 - 60 °C
Weight & dimensions1 differ
Width432 mm432 mm
DepthDiffers305 mm216 mm
Height44 mm44 mm
Packaging dataidentical
Package weight5.44 kg5.44 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons