Product comparison · 2 power distribution units (pdus)

LogiLink PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black vs Vertiv Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19

Add a product
  • 11specifications compared
  • 10differ
  • 1identical
  • 18known for one product only

Key differences

  • PDU types
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Basic
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:Monitored
  • Rack capacity
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:0U
  • AC outlets quantity
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:42 AC outlet(s)
  • AC outlet types
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:C13 coupler
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:C13 coupler, C19 coupler
  • Nominal input voltage
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:230 V
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:230/400 V
  • AC input frequency
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:50 - 60 Hz
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:50 Hz
  • Maximum current
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:10 A
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:16 A
  • Width
    • PDU8A01 power distribution unit (PDU) 8 AC outlet(s) 1U Black:482 mm
    • Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19:1683 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PDU8A01, Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x16A, outputs (36)C13 | (6)C19
29 specifications
Design2 differ
PDU typesDiffersBasicMonitored
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacityDiffers1U0U
MountingKnown for oneUnknown — not stated by the sourceVertical
Product colourBlackBlack
Housing materialKnown for onePolypropylene (PP)Unknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)42 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Output connectionsKnown for oneUnknown — not stated by the source36 x C13 & 6 x C19
Featuresidentical
LED indicatorsKnown for oneUnknown — not stated by the sourceNo
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Management platformKnown for oneUnknown — not stated by the sourceWeb UI, HTTP, HTTPS (TLS 1.2), SMTP, SMTPS (TLS 1.2), ICMP, DHCP, IPv4, IPv6, Syslog, SNMP v1/v2c/v3, JSON, JSON, API, RSTP
Power3 differ
Nominal input voltageDiffers230 V230/400 V
AC input frequencyDiffers50 - 60 Hz50 Hz
Maximum currentDiffers10 A16 A
Load capacityKnown for oneUnknown — not stated by the source11000 VA
Surge protectionKnown for oneYesUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationKnown for oneUnknown — not stated by the sourceCE, RoHS, CB certificate
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 60 °C
Weight & dimensions3 differ
WidthDiffers482 mm1683 mm
DepthDiffers45 mm51 mm
HeightDiffers45 mm51 mm
WeightKnown for oneUnknown — not stated by the source7.26 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source1829 mm
Package depthKnown for oneUnknown — not stated by the source223 mm
Package heightKnown for oneUnknown — not stated by the source159 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.