Product comparison · 2 power distribution units (pdus)

ATEN PE8208AV power distribution unit (PDU) 8 AC outlet(s) 1U Black vs ATEN 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

Add a product
  • 32specifications compared
  • 5differ
  • 27identical
  • 1known for one product only

Key differences

  • Power plug
    • PE8208AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:NEMA 5-20P
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:NEMA L6-20P
  • AC outlet types
    • PE8208AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:NEMA 5–20R
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:C13 coupler, C19 coupler
  • AC input frequency
    • PE8208AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:50/60 Hz
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:50 - 60 Hz
  • Maximum current
    • PE8208AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:12 A
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:20 A
  • Load capacity
    • PE8208AV power distribution unit (PDU) 8 AC outlet(s) 1U Black:2400 VA
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:4160 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of PE8208AV, PE8208B
33 specifications
Designidentical
PDU typesMetered, SwitchedMetered, Switched
Rack capacity1U1U
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantity8 AC outlet(s)8 AC outlet(s)
Power plugDiffersNEMA 5-20PNEMA L6-20P
AC outlet typesDiffersNEMA 5–20RC13 coupler, C19 coupler
Ethernet LAN (RJ-45) ports11
Featuresidentical
Cable length3 m3 m
Security algorithms128-bit SSL128-bit SSL
Password protectionYesYes
Management featuresidentical
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Firmware upgradeableYesYes
Management protocolsSNMP Manager V3SNMP Manager V3
Supported network protocolsTCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, TelnetTCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, Telnet
Power3 differ
Nominal input voltage100 - 240 V100 - 240 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers12 A20 A
Nominal output voltage100 - 240 V100 - 240 V
Load capacityDiffers2400 VA4160 VA
Maximum powerKnown for one1440 WUnknown — not stated by the source
Circuit breakerYesYes
Certificatesidentical
Compliance certificatesFederal Communications Commission (FCC)Federal Communications Commission (FCC)
Sustainabilityidentical
Sustainability complianceYesYes
Operational conditionsidentical
Operating temperature (T-T)0 - 50 °C0 - 50 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)0 - 80%0 - 80%
Weight & dimensionsidentical
Width220.4 mm220.4 mm
Depth432.4 mm432.4 mm
Height44 mm44 mm
Weight2.84 kg2.84 kg
Packaging contentidentical
Cables includedACAC
ManualYesYes
Rack mount kitYesYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons