Product comparison · 2 power distribution units (pdus)

ATEN PE6216A power distribution unit (PDU) 16 AC outlet(s) Black vs ATEN 16A 16 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software

Add a product
  • 18specifications compared
  • 5differ
  • 13identical
  • 8known for one product only

Key differences

  • PDU types
    • PE6216A power distribution unit (PDU) 16 AC outlet(s) Black:Basic
    • 16A 16 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Monitored
  • AC outlet types
    • PE6216A power distribution unit (PDU) 16 AC outlet(s) Black:NEMA 5–15R, NEMA 5–20R
    • 16A 16 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:C13 coupler, C19 coupler
  • LED indicators
    • PE6216A power distribution unit (PDU) 16 AC outlet(s) Black:LAN, Power, Status
    • 16A 16 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Yes
  • Nominal input voltage
    • PE6216A power distribution unit (PDU) 16 AC outlet(s) Black:100 - 120 V
    • 16A 16 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:100-240 V
  • Operating temperature (T-T)
    • PE6216A power distribution unit (PDU) 16 AC outlet(s) Black:0 - 50 °C
    • 16A 16 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:0 - 40 °C

Side by side

Differences highlightedShow differences only (on)
Comparison of PE6216A, PE6216G
26 specifications
Design1 differ
PDU typesDiffersBasicMonitored
Rack capacityKnown for oneUnknown — not stated by the source0U
MountingKnown for oneUnknown — not stated by the sourceVertical
Ports & interfaces1 differ
AC outlet typesDiffersNEMA 5–15R, NEMA 5–20RC13 coupler, C19 coupler
Output connectionsKnown for oneUnknown — not stated by the source14 x IEC 320 C13 & 2 x IEC 320 C19
Features1 differ
LED indicatorsDiffersLAN, Power, StatusYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceSNMP V1, V2, V3
Power1 differ
Nominal input voltageDiffers100 - 120 V100-240 V
Nominal output voltageKnown for one100-120 VUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 50 °C0 - 40 °C
Storage relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons