Product comparison · 2 power distribution units (pdus)

ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s) vs Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V

Add a product
  • 11specifications compared
  • 11differ
  • 0identical
  • 16known for one product only

Key differences

The Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V has 16 A more maximum current than the ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s) (32 A vs 16 A). The ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s) has 10 mm more width than the Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V (66 mm vs 56 mm). The ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s) has 1,274.8 mm more depth than the Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V (1324.8 mm vs 50 mm). AC outlets quantity: 16 AC outlet(s) on the ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s), 24 AC outlet(s) on the Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V. AC outlet types: C13 coupler, C19 coupler on the ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s), C13 coupler on the Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V.

  • AC outlets quantity
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):16 AC outlet(s)
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:24 AC outlet(s)
  • AC outlet types
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):C13 coupler, C19 coupler
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:C13 coupler
  • Nominal input voltage
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):100-240 V
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:230-400 V
  • Maximum current
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):16 A
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:32 A
  • Operating temperature (T-T)
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):0 - 40 °C
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:0 - 60 °C
  • Storage temperature (T-T)
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):-20 - 60 °C
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:-25 - 85 °C
  • Operating relative humidity (H-H)
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):0 - 80%
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:5 - 95%
  • Width
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):66 mm
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:56 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of PE6216, MPHM1245
27 specifications
Designidentical
On/off switchKnown for oneYesUnknown — not stated by the source
PDU typesKnown for oneUnknown — not stated by the sourceMetered
Rack capacityKnown for oneUnknown — not stated by the source0U
Product colourKnown for oneUnknown — not stated by the sourceBlack
Ports & interfaces2 differ
AC outlets quantityDiffers16 AC outlet(s)24 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler
Input connection typeKnown for oneIEC 60320 C20Unknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Featuresidentical
Cable lengthKnown for one3 mUnknown — not stated by the source
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Power2 differ
Nominal input voltageDiffers100-240 V230-400 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers16 A32 A
Nominal output voltageKnown for one110-240 VUnknown — not stated by the source
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum powerKnown for one100 WUnknown — not stated by the source
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
CertificationDiffersCE C-Tick TUV-CB GOSTUL, CSA, CE, REACH, FCC Class A, CB, WEEE, ISTA
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 60 °C
Storage temperature (T-T)Differs-20 - 60 °C-25 - 85 °C
Operating relative humidity (H-H)Differs0 - 80%5 - 95%
Weight & dimensions3 differ
WidthDiffers66 mm56 mm
DepthDiffers1324.8 mm50 mm
HeightDiffers44 mm1736.5 mm
WeightKnown for one3.73 kgUnknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceWeb, CLI, SNMP, SSH, Telnet

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.