ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s) vs Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V

Add a product
  • 11specifications compared
  • 10differ
  • 1identical
  • 17known for one product only

Key differences

The Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V has 16 A more maximum current than the ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s) (32 A vs 16 A). The ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s) has 10 mm more width than the Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V (66 mm vs 56 mm). The ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s) has 1,274.8 mm more depth than the Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V (1324.8 mm vs 50 mm). AC outlets quantity: 16 AC outlet(s) on the ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s), 24 AC outlet(s) on the Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V. Nominal input voltage: 100-240 V on the ATEN PE6216 power distribution unit (PDU) 16 AC outlet(s), 230-400 V on the Vertiv MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V.

  • AC outlets quantity
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):16 AC outlet(s)
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:24 AC outlet(s)
  • Nominal input voltage
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):100-240 V
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:230-400 V
  • Maximum current
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):16 A
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:32 A
  • Operating temperature (T-T)
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):0 - 40 °C
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:0 - 60 °C
  • Storage temperature (T-T)
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):-20 - 60 °C
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:-25 - 85 °C
  • Operating relative humidity (H-H)
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):0 - 80%
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:5 - 95%
  • Width
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):66 mm
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:56 mm
  • Depth
    • PE6216 power distribution unit (PDU) 16 AC outlet(s):1324.8 mm
    • MPH2 Rack PDU, outlet metered, 0U, input IEC 60309 230/400V:50 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of PE6216, MPHM1145
28 specifications
Designidentical
PDU typesKnown for oneUnknown — not stated by the sourceMetered
Rack capacityKnown for oneUnknown — not stated by the source0U
Product colourKnown for oneUnknown — not stated by the sourceBlack
On/off switchKnown for oneYesUnknown — not stated by the source
Ports & interfaces1 differ
AC outlets quantityDiffers16 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Output connectionsKnown for oneUnknown — not stated by the source18 x C13 & 6 x C19
Input connection typeKnown for oneIEC 60320 C20Unknown — not stated by the source
Featuresidentical
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for one3 mUnknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceWeb, CLI, SNMP, SSH, Telnet
Power2 differ
Nominal input voltageDiffers100-240 V230-400 V
Maximum currentDiffers16 A32 A
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Nominal output voltageKnown for one110-240 VUnknown — not stated by the source
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum powerKnown for one100 WUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationDiffersCE C-Tick TUV-CB GOSTUL, CSA, CE, REACH, FCC Class A, CB, WEEE, ISTA
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 60 °C
Storage temperature (T-T)Differs-20 - 60 °C-25 - 85 °C
Operating relative humidity (H-H)Differs0 - 80%5 - 95%
Weight & dimensions3 differ
WidthDiffers66 mm56 mm
DepthDiffers1324.8 mm50 mm
HeightDiffers44 mm1736.5 mm
WeightKnown for one3.73 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.