Product comparison · 2 power distribution units (pdus)

ATEN PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black vs Vertiv Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black

Add a product
  • 21specifications compared
  • 16differ
  • 5identical
  • 14known for one product only

Key differences

The ATEN PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1 U more rack capacity than the Vertiv Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black (1U vs 0U). The Vertiv Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black has 40 A more maximum current than the ATEN PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black (60 A vs 20 A). The ATEN PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black has 374.4 mm more width than the Vertiv Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black (432.4 mm vs 58 mm). PDU types: Metered on the ATEN PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black, Switched on the Vertiv Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black. Mounting: Horizontal on the ATEN PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black, Vertical on the Vertiv Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black.

  • PDU types
    • PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black:Metered
    • Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:Switched
  • Rack capacity
    • PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
    • Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:0U
  • Mounting
    • PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black:Horizontal
    • Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:Vertical
  • AC outlets quantity
    • PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
    • Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
  • Power plug
    • PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black:NEMA L5-20P
    • Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:IEC 60309
  • AC outlet types
    • PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black:NEMA 5-20R
    • Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:C13 coupler, C19 coupler
  • Nominal input voltage
    • PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black:100 - 240 V
    • Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:100-120/200-240 V
  • AC input frequency
    • PE6208AVX-AT power distribution unit (PDU) 8 AC outlet(s) 1U Black:50 - 60 Hz
    • Geist MNU3EGW1-24PBB8-6PS15B0A10-S-A power distribution unit (PDU) 24 AC outlet(s) 0U Black:50/60 Hz

Side by side

Differences highlightedShow differences only (on)
Comparison of PE6208AVX-AT, MNU3EGW1-24PBB8-6PS15B0A10-S-A
35 specifications
Design3 differ
PDU typesDiffersMeteredSwitched
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacityDiffers1U0U
MountingDiffersHorizontalVertical
DisplayKnown for oneUnknown — not stated by the sourceLED
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers8 AC outlet(s)24 AC outlet(s)
Power plugDiffersNEMA L5-20PIEC 60309
AC outlet typesDiffersNEMA 5-20RC13 coupler, C19 coupler
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Security algorithmsKnown for one128-bit SSLUnknown — not stated by the source
Password protectionKnown for oneYesUnknown — not stated by the source
Management features1 differ
Supported network protocolsDiffersTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, PingDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Management protocolsKnown for oneSNMP V1, V2, V3, TelnetUnknown — not stated by the source
Power4 differ
Nominal input voltageDiffers100 - 240 V100-120/200-240 V
AC input frequencyDiffers50 - 60 Hz50/60 Hz
Maximum currentDiffers20 A60 A
Load capacityKnown for oneUnknown — not stated by the source208 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Power protection featuresDiffersOverloadOver current
Certificates1 differ
CertificationDiffersFCC, TUV-CB, cTUVus, ULRoHS Compliant FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 50 °C0 - 60 °C
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers432.4 mm58 mm
DepthDiffers363.9 mm66 mm
HeightDiffers44 mm1778 mm
WeightKnown for one4.67 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source9.98 kg
Packaging contentidentical
Cables includedKnown for oneAC, LAN (RJ-45)Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons