ATEN 1U AV 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software vs ATEN 32A 24 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software

Add a product
  • 22specifications compared
  • 15differ
  • 7identical
  • 13known for one product only

Key differences

  • PDU types
    • 1U AV 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Metered
    • 32A 24 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Metered, Switched
  • Rack capacity
    • 1U AV 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:1U
    • 32A 24 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:0U
  • Mounting
    • 1U AV 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Horizontal
    • 32A 24 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Vertical
  • AC outlets quantity
    • 1U AV 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:8 AC outlet(s)
    • 32A 24 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:24 AC outlet(s)
  • Power plug
    • 1U AV 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:NEMA L5-20P
    • 32A 24 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:IEC 60309
  • AC outlet types
    • 1U AV 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:NEMA 5-20R
    • 32A 24 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:C13 coupler, C19 coupler
  • Cable length
    • 1U AV 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:3 m
    • 32A 24 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:1.6 m
  • Nominal input voltage
    • 1U AV 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:100 - 240 V
    • 32A 24 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:100-240 V

Side by side

Differences highlightedShow differences only (on)
Comparison of PE6208AV-AT-G, PE6324LG-AX
35 specifications
Design3 differ
PDU typesDiffersMeteredMetered, Switched
TypeKnown for oneUnknown — not stated by the sourceSingle-phase
Rack capacityDiffers1U0U
MountingDiffersHorizontalVertical
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Ports & interfaces3 differ
AC outlets quantityDiffers8 AC outlet(s)24 AC outlet(s)
Power plugDiffersNEMA L5-20PIEC 60309
AC outlet typesDiffersNEMA 5-20RC13 coupler, C19 coupler
Serial ports quantityKnown for one1Unknown — not stated by the source
Features1 differ
Cable lengthDiffers3 m1.6 m
Security algorithmsKnown for one128-bit SSLUnknown — not stated by the source
Password protectionKnown for oneYesUnknown — not stated by the source
Management features1 differ
MonitoringKnown for oneUnknown — not stated by the sourceHumidity, Power, Temperature
Supported network protocolsDiffersTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, PingTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2&V3, Telnet
Management protocolsKnown for oneSNMP V1, V2, V3, TelnetUnknown — not stated by the source
Power2 differ
Nominal input voltageDiffers100 - 240 V100-240 V
Maximum currentDiffers20 A32 A
Nominal output voltageKnown for oneUnknown — not stated by the source100-240 V
Load capacityKnown for oneUnknown — not stated by the source7360 VA
Certificates1 differ
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationDiffersFCC, J55032CE, CE-LVD
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 50 °C0 - 40 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Weight & dimensions3 differ
WidthDiffers432.4 mm66 mm
DepthDiffers363.9 mm1775 mm
WeightDiffers4.67 kg5.76 kg
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Cables includedKnown for oneAC, LAN (RJ-45)Unknown — not stated by the source