Product comparison · 2 power distribution units (pdus)

ATEN PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black vs Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black

Add a product
  • 17specifications compared
  • 12differ
  • 5identical
  • 14known for one product only

Key differences

The ATEN PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black has 12 A more maximum current than the Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black (32 A vs 20 A). The ATEN PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black has 7,130 VA more load capacity than the Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black (7360 VA vs 230 VA). The ATEN PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black has 1,681 mm more width than the Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black (1775 mm vs 94 mm). PDU types: Metered on the ATEN PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black, Switched on the Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black. AC outlets quantity: 42 AC outlet(s) on the ATEN PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black, 48 AC outlet(s) on the Vertiv Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black.

  • PDU types
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:Metered
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:Switched
  • AC outlets quantity
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:48 AC outlet(s)
  • Nominal input voltage
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:100-240 V
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:200-240/346-415 V
  • AC input frequency
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:50-60 Hz
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:50/60 Hz
  • Maximum current
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:32 A
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:20 A
  • Load capacity
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:7360 VA
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:230 VA
  • Operating temperature (T-T)
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:0 - 40 °C
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:0 - 60 °C
  • Width
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:1775 mm
    • Geist MNS3EHW0-48PZB3-2PS56B0A10-S-A power distribution unit (PDU) 48 AC outlet(s) 0U Black:94 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of PE5342TG-AX, MNS3EHW0-48PZB3-2PS56B0A10-S-A
31 specifications
Design1 differ
PDU typesDiffersMeteredSwitched
TypeKnown for oneUnknown — not stated by the sourceThree-phase
MountingKnown for oneUnknown — not stated by the sourceVertical
DisplayKnown for oneUnknown — not stated by the sourceLED
On/off switchKnown for oneUnknown — not stated by the sourceNo
Ports & interfaces1 differ
AC outlets quantityDiffers42 AC outlet(s)48 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Management features1 differ
Supported network protocolsDiffersTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, SNMP V1,V2&V3DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power4 differ
Nominal input voltageDiffers100-240 V200-240/346-415 V
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers32 A20 A
Load capacityDiffers7360 VA230 VA
Certificates1 differ
CertificationDiffersCE, CE-LVDRoHS Compliant FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 60 °C
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers1775 mm94 mm
DepthDiffers56 mm66 mm
HeightDiffers48 mm1778 mm
WeightKnown for one5.57 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source8.16 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons