Product comparison · 2 power distribution units (pdus)

ATEN PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black vs Vertiv Geist MNS3EGW1-36PT68-4CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black

Add a product
  • 17specifications compared
  • 12differ
  • 5identical
  • 15known for one product only

Key differences

  • PDU types
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:Metered
    • Geist MNS3EGW1-36PT68-4CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:Switched
  • AC outlets quantity
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
    • Geist MNS3EGW1-36PT68-4CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:36 AC outlet(s)
  • Nominal input voltage
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:100-240 V
    • Geist MNS3EGW1-36PT68-4CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:200-240 V
  • AC input frequency
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:50-60 Hz
    • Geist MNS3EGW1-36PT68-4CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:50/60 Hz
  • Maximum current
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:32 A
    • Geist MNS3EGW1-36PT68-4CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:35 A
  • Load capacity
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:7360 VA
    • Geist MNS3EGW1-36PT68-4CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:208 VA
  • Operating temperature (T-T)
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:0 - 40 °C
    • Geist MNS3EGW1-36PT68-4CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:0 - 60 °C
  • Width
    • PE5342TG-AX power distribution unit (PDU) 42 AC outlet(s) 0U Black:1775 mm
    • Geist MNS3EGW1-36PT68-4CS15A0A10-S-A power distribution unit (PDU) 36 AC outlet(s) 0U Black:51 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PE5342TG-AX, MNS3EGW1-36PT68-4CS15A0A10-S-A
32 specifications
Design1 differ
PDU typesDiffersMeteredSwitched
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacity0U0U
MountingKnown for oneUnknown — not stated by the sourceVertical
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLED
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces1 differ
AC outlets quantityDiffers42 AC outlet(s)36 AC outlet(s)
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) ports11
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable length3 m3 m
Management features1 differ
Supported network protocolsDiffersTCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, SNMP V1,V2&V3DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power4 differ
Nominal input voltageDiffers100-240 V200-240 V
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers32 A35 A
Load capacityDiffers7360 VA208 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
CertificationDiffersCE, CE-LVDRoHS Compliant FCC Part 15 Class A Conformance UL & c-UL Listed 62368-1
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 60 °C
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers1775 mm51 mm
DepthDiffers56 mm66 mm
HeightDiffers48 mm1829 mm
WeightKnown for one5.57 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source9.07 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons