Product comparison · 2 power distribution units (pdus)

ATEN PE5324G power distribution unit (PDU) 24 AC outlet(s) 0U Black vs CyberPower PDU30SWHVT19ATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black

Add a product
  • 19specifications compared
  • 15differ
  • 4identical
  • 11known for one product only

Key differences

  • PDU types
    • PE5324G power distribution unit (PDU) 24 AC outlet(s) 0U Black:Metered
    • PDU30SWHVT19ATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black:Switched
  • Rack capacity
    • PE5324G power distribution unit (PDU) 24 AC outlet(s) 0U Black:0U
    • PDU30SWHVT19ATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black:2U
  • AC outlets quantity
    • PE5324G power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
    • PDU30SWHVT19ATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black:19 AC outlet(s)
  • Cable length
    • PE5324G power distribution unit (PDU) 24 AC outlet(s) 0U Black:1.6 m
    • PDU30SWHVT19ATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black:3 m
  • Management platform
    • PE5324G power distribution unit (PDU) 24 AC outlet(s) 0U Black:SNMP v1/v2/v3
    • PDU30SWHVT19ATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black:SNMP/HTTP
  • Nominal input voltage
    • PE5324G power distribution unit (PDU) 24 AC outlet(s) 0U Black:100-240 V
    • PDU30SWHVT19ATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black:200-240 V
  • Maximum current
    • PE5324G power distribution unit (PDU) 24 AC outlet(s) 0U Black:32 A
    • PDU30SWHVT19ATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black:30 A
  • Nominal output voltage
    • PE5324G power distribution unit (PDU) 24 AC outlet(s) 0U Black:100-240 V
    • PDU30SWHVT19ATNET power distribution unit (PDU) 19 AC outlet(s) 2U Black:200-240 V

Side by side

Differences highlightedShow differences only (on)
Comparison of PE5324G, PDU30SWHVT19ATNET
30 specifications
Design2 differ
PDU typesDiffersMeteredSwitched
Rack capacityDiffers0U2U
Housing materialKnown for oneMetalUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)19 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler, C19 coupler, NEMA L6-30R
Serial ports quantityKnown for oneUnknown — not stated by the source1
Power plugKnown for oneIEC 60309Unknown — not stated by the source
Output connectionsKnown for one21 x IEC 320 C13 & 3 x IEC 320 C19Unknown — not stated by the source
Features1 differ
Cable lengthDiffers1.6 m3 m
Management features1 differ
Management platformDiffersSNMP v1/v2/v3SNMP/HTTP
MonitoringKnown for oneHumidity, TemperatureUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers100-240 V200-240 V
Maximum currentDiffers32 A30 A
Nominal output voltageDiffers100-240 V200-240 V
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationKnown for oneUnknown — not stated by the sourceUL60950_1 certified by ETL (USA), CSA C22.2 (Canada), FCC Class A
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 45 °C
Storage temperature (T-T)Differs-20 - 60 °C-15 - 45 °C
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers66 mm433 mm
DepthDiffers1775 mm236.2 mm
HeightDiffers44 mm88.9 mm
WeightDiffers6.3 kg7.6 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons