Product comparison · 2 power distribution units (pdus)

ATEN 1U Basic PDU with Surge Protection vs ATEN 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

Add a product
  • 21specifications compared
  • 9differ
  • 12identical
  • 17known for one product only

Key differences

  • PDU types
    • 1U Basic PDU with Surge Protection:Basic
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:Metered, Switched
  • AC outlets quantity
    • 1U Basic PDU with Surge Protection:18 AC outlet(s)
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:8 AC outlet(s)
  • AC outlet types
    • 1U Basic PDU with Surge Protection:C13 coupler
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:C13 coupler, C19 coupler
  • Load capacity
    • 1U Basic PDU with Surge Protection:4800 VA
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:4160 VA
  • Operating temperature (T-T)
    • 1U Basic PDU with Surge Protection:0 - 40 °C
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:0 - 50 °C
  • Width
    • 1U Basic PDU with Surge Protection:44.4 mm
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:220.4 mm
  • Depth
    • 1U Basic PDU with Surge Protection:482 mm
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:432.4 mm
  • Height
    • 1U Basic PDU with Surge Protection:88.5 mm
    • 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU:44 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of PE0218SB, PE8208B
38 specifications
Design1 differ
PDU typesDiffersBasicMetered, Switched
Housing materialKnown for oneAluminiumUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers18 AC outlet(s)8 AC outlet(s)
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Featuresidentical
Security algorithmsKnown for oneUnknown — not stated by the source128-bit SSL
Password protectionKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Firmware upgradeableKnown for oneUnknown — not stated by the sourceYes
Management protocolsKnown for oneUnknown — not stated by the sourceSNMP Manager V3
Supported network protocolsKnown for oneUnknown — not stated by the sourceTCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, Telnet
Power1 differ
Nominal output voltageKnown for oneUnknown — not stated by the source100 - 240 V
Load capacityDiffers4800 VA4160 VA
Circuit breakerKnown for oneUnknown — not stated by the sourceYes
Block 1 output currentKnown for one20 AUnknown — not stated by the source
Power protection featuresKnown for oneOver currentUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 80%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers44.4 mm220.4 mm
DepthDiffers482 mm432.4 mm
HeightDiffers88.5 mm44 mm
WeightDiffers1.26 kg2.84 kg
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons