Product comparison · 2 power distribution units (pdus)

APC SBP3000RM power distribution unit (PDU) 5 AC outlet(s) Black vs APC Switched Rack PDU

Add a product
  • 26specifications compared
  • 22differ
  • 4identical
  • 12known for one product only

Key differences

  • AC outlets quantity
    • SBP3000RM power distribution unit (PDU) 5 AC outlet(s) Black:5 AC outlet(s)
    • Switched Rack PDU:24 AC outlet(s)
  • Power plug
    • SBP3000RM power distribution unit (PDU) 5 AC outlet(s) Black:NEMA L5-30P
    • Switched Rack PDU:IEC309
  • Nominal input voltage
    • SBP3000RM power distribution unit (PDU) 5 AC outlet(s) Black:120 V
    • Switched Rack PDU:230 V
  • Nominal output voltage
    • SBP3000RM power distribution unit (PDU) 5 AC outlet(s) Black:120 V
    • Switched Rack PDU:230 V
  • Load capacity
    • SBP3000RM power distribution unit (PDU) 5 AC outlet(s) Black:3000 VA
    • Switched Rack PDU:7680 VA
  • Maximum input current per phase
    • SBP3000RM power distribution unit (PDU) 5 AC outlet(s) Black:30 A
    • Switched Rack PDU:32 A
  • Maximum total current draw per phase
    • SBP3000RM power distribution unit (PDU) 5 AC outlet(s) Black:30 A
    • Switched Rack PDU:32 A
  • Operating temperature (T-T)
    • SBP3000RM power distribution unit (PDU) 5 AC outlet(s) Black:0 - 40 °C
    • Switched Rack PDU:-5 - 45 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of SBP3000RM, Switched Rack PDU
38 specifications
Design1 differ
PDU typesDiffersBasicMetered, Metered-by-outlet, Switched
TypeKnown for oneUnknown — not stated by the sourceSingle-phase
Rack capacityKnown for oneUnknown — not stated by the source0U
MountingKnown for oneUnknown — not stated by the sourceVertical
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers5 AC outlet(s)24 AC outlet(s)
Power plugDiffersNEMA L5-30PIEC309
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler, C19 coupler
Output connectionsKnown for one4 x NEMA 5-20R & 1 x NEMA L5-30RUnknown — not stated by the source
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Outlet controlKnown for oneUnknown — not stated by the sourceLock-out, Recycle, Turn off, Turn on
Power5 differ
Nominal input voltageDiffers120 V230 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentKnown for oneUnknown — not stated by the source32 A
Nominal output voltageDiffers120 V230 V
Load capacityDiffers3000 VA7680 VA
Maximum input current per phaseDiffers30 A32 A
Maximum total current draw per phaseDiffers30 A32 A
Maximum powerKnown for oneUnknown — not stated by the source7680 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersTUVEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE
Operational conditions5 differ
Operating temperature (T-T)Differs0 - 40 °C-5 - 45 °C
Storage temperature (T-T)Differs-15 - 45 °C-25 - 65 °C
Operating relative humidity (H-H)Differs0 - 95%5 - 95%
Storage relative humidity (H-H)Differs0 - 95%5 - 95%
Operating altitudeDiffers0 - 4500 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Weight & dimensions4 differ
WidthDiffers432 mm56 mm
DepthDiffers76 mm51 mm
HeightDiffers89 mm1829 mm
WeightDiffers4.45 kg8.23 kg
Packaging data4 differ
Package weightDiffers5.27 kg10.5 kg
Package widthDiffers463 mm162 mm
Package depthDiffers295 mm118 mm
Package heightDiffers151 mm2038 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for oneUnknown — not stated by the source8595.81

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons