Product comparison · 2 power distribution units (pdus)

APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk vs Vertiv Liebert MPX Rack PDU, output module, elementary, 0U

Add a product
  • 8specifications compared
  • 6differ
  • 2identical
  • 19known for one product only

Key differences

The APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk has 170 V more nominal input voltage than the Vertiv Liebert MPX Rack PDU, output module, elementary, 0U (400 V vs 230 V). The Vertiv Liebert MPX Rack PDU, output module, elementary, 0U has 16,660 W more maximum power than the APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk (27700 W vs 11040 W). PDU types: Metered, Metered-by-outlet, Switched on the APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk, Metered on the Vertiv Liebert MPX Rack PDU, output module, elementary, 0U. Product colour: Blue on the APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk, Aluminium, Grey on the Vertiv Liebert MPX Rack PDU, output module, elementary, 0U. AC outlets quantity: 24 AC outlet(s) on the APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk, 4 AC outlet(s) on the Vertiv Liebert MPX Rack PDU, output module, elementary, 0U.

  • Product colour
    • Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk:Blue
    • Liebert MPX Rack PDU, output module, elementary, 0U:Aluminium, Grey
  • AC outlets quantity
    • Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk:24 AC outlet(s)
    • Liebert MPX Rack PDU, output module, elementary, 0U:4 AC outlet(s)
  • AC outlet types
    • Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk:C13 coupler, C19 coupler
    • Liebert MPX Rack PDU, output module, elementary, 0U:C19 coupler
  • Nominal input voltage
    • Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk:400 V
    • Liebert MPX Rack PDU, output module, elementary, 0U:230 V
  • Maximum power
    • Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk:11040 W
    • Liebert MPX Rack PDU, output module, elementary, 0U:27700 W

Side by side

Differences highlightedShow differences only (on)
Comparison of Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk, MPXBRM-EEBC4O1N
27 specifications
Design2 differ
PDU typesDiffersMetered, Metered-by-outlet, SwitchedMetered
Housing materialKnown for oneUnknown — not stated by the sourceAluminium, Steel
Product colourDiffersBlueAluminium, Grey
On/off switchKnown for oneUnknown — not stated by the sourceYes
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)4 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerC19 coupler
Power plugKnown for oneIEC309Unknown — not stated by the source
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Power2 differ
Nominal input voltageDiffers400 V230 V
Maximum powerDiffers11040 W27700 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityKnown for one11040 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one16 AUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationKnown for oneUnknown — not stated by the sourceUL, CSA, CE, REACH, FCC, CB, WEEE, ISTA
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 55 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-25 - 85 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Weight & dimensionsidentical
WeightKnown for oneUnknown — not stated by the source1.03 kg
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Outlet controlKnown for oneLock-out, Recycle, Turn off, Turn onUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.